Feider Machines FG4500 Instruction Manual

Feider Machines FG4500 Instruction Manual

Gasoline generator

Advertisement

Quick Links

ORIGINAL INSTRUCTION > EN
Gasoline Generator
Instruction Manual
Model: FG4500
Feider France
32, rue Aristide Bergès - ZI 31270 Cugnaux - France
Made in PRC 2017
Warning: Please read the manual carefully before using the unit!
1

Advertisement

Table of Contents
loading

Summary of Contents for Feider Machines FG4500

  • Page 1 ORIGINAL INSTRUCTION > EN Gasoline Generator Instruction Manual Model: FG4500 Feider France 32, rue Aristide Bergès - ZI 31270 Cugnaux - France Made in PRC 2017 Warning: Please read the manual carefully before using the unit!
  • Page 2: Table Of Contents

    CONTENTS 1. SAFETY INSTRUCTION 2. COMPONENT IDENTIFICATION 3. CONTROLS 1) Engine Switch 2) Recoil Starter 3) Fuel Valve 4) Choke 5) Circuit Breaker 6) Ground Terminal 7) Oil Alert System 4. GENERATOR USE 1) Connections to a Building's Electrical System 2) Ground System 3) AC Applications 4) AC Operation...
  • Page 3: Safety Instruction

    1. SAFETY INSTRUCTION Warning: 1. Attention! Exhaust gases are toxic. Do not operate the generator in a room without ventilation system! 2. Children should be protected by keeping them at a safe distance from the generator set! 3. Refilling of the generating sets are not allowed during the operation! 4.
  • Page 4  Run the generator in respect of the power indicated in the user’s manual. Do not run the generator with an overload or at excessive speed.  The silencer of the generator becomes extremely hot when the motor runs or even for a time after it has stopped.
  • Page 5  If you swallow fuel by mistake, if you inhale fuel vapours or if you get drops of fuel in your eyes, see a doctor immediately. If a certain quantity of fuel is spilt on your skin or clothing, wash or change your clothes. ...
  • Page 6 in contact with the line during a power cut. Also, when the public power supply is re-established, the generator can explode, catch fire or generate fires in the building’s electrical installation. Before connecting electrical devices to the generator, make sure that their voltage specifications and frequency of functioning correspond to the technical characteristics of the generator.
  • Page 7: Component Identification

    Ground connection It is forbidden to run the generator in an enclosed room because exhaust emissions can lead humans or animals to coma to death. This symbol indicates the surface is very hot and not touching Keep away from the machine Exhaust emissions are harmful to health of body No naked fire near the machine! Do not connect with the electricity system.
  • Page 8: Controls

    3. CONTROLS 1) Engine Switch To start and stop the engine. Switch position: OFF: To Stop the engine. Key can be removed/inserted. ON: To run the engine after starting. START: To start the engine by turning the starter motor. With Electric Starter Without Electric Starter Return the key to the ON position once the engine has started.
  • Page 9 4) Choke The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke lever or choke rod manually. Move the lever or the rod to the CLOSE position to enrich the mixture. 5) Circuit Breaker The circuit breaker will automatically switch OFF if there is a short circuit or a significant overload of the generator at the receptacle.
  • Page 10: Generator Use

    7) Oil Alert System The oil alert system is designed to prevent engine damage caused by an insufficient amount of oil in the crankcase. Before the oil level in the crankcase can fall below a safe limit, the oil alert system will automatically shut down the engine (the engine switch will remain in the ON position).
  • Page 11 Special Requirements There may be Federal or State Occupational Safety and Health Administration (OSHA) regulations, local codes, or ordinances that apply to the intended use of the generator. Please consult a qualified electrician, electrical inspector, or the local agency having jurisdiction. •...
  • Page 12 DC Terminals The DC terminals may ONLY be used for charging 12 volt automotive type batteries. The terminals are colored red to identify the positive (+) terminal and black to identify the negative (- ) terminal. The battery must be connected to the generator DC terminals with the proper polarity (battery positive to generator red terminal and battery negative to the generator black terminal).
  • Page 13 NOTICE Do not start the vehicle while the battery charging cables are connected and the generator is running. The vehicle or the generator may be damaged. An overloaded DC circuit will fuse the DC fuse, if this happens, replace fuse. An overloaded DC circuit, excessive current draw by the battery, or a wiring problem will trip the DC circuit protector (PUSH button extends out).
  • Page 14: Pre-Operation Check

    5. PRE-OPERATION CHECK 1) Engine oil NOTICE Engine oil is a major factor affecting engine performance and service life. Non-detergent and 2-stroke engine oils will damage the engine and are not recommended. Check the oil level BEFORE EACH USE with the generator on a level surface with the engine stopped.
  • Page 15 2) Fuel Recommendation 1. Check the fuel level gauge. 2. Refill the tank if the fuel level is low. Do not fill above the shoulder of the fuel strainer. WARNING • Gasoline is extremely flammable and is explosive under certain conditions. •...
  • Page 16: Starting/Stopping The Engine

    Oxygenated Fuels Some gasoline are blended with alcohol or an ether compound to increase the octane. These gasoline are collectively referred to as oxygenated fuels. Some areas of the United States use oxygenated fuels to help meet clean air standards. If you use an oxygenated fuel, be sure its pump octane rating is 86 or higher.
  • Page 17: Maintenance

    • With recoil starter: Turn the engine switch to the ON position. Pull the starter grip until compression is felt, then pull briskly. NOTICE Do not allow the starter grip to snap back against the engine. Return it gently to prevent damage to the starter or housing.
  • Page 18 Periodic maintenance and adjustment is necessary to keep the generator in good operating condition. Perform the service and inspection at the intervals shown in the Maintenance schedule below. 1) MAINTENANCE SCHEDULE REGULAR SERVICE PERIOD Performed at Each use First month Every 3 Every 6 Every year...
  • Page 19 NOTE: Diagrams may vary according to the types. 3) Engine oil change Drain the oil while the engine is warm to assure complete and rapid draining 1. Remove the drain plug and sealing washer, oil filler cap, and drain the oil 2.
  • Page 20 WARNING Using gasoline or flammable solvent to clean the filter element can cause a fire or explosion. Use only soapy water or nonflammable solvent. NOTICE Never run the generator without the air cleaner. Rapid engine wear will result. 1) Unsnap the air cleaner cover clips, remove the air cleaner cover, and remove the element. 2) Wash the element in a solution of household detergent and warm water, then rinse thoroughly;...
  • Page 21 5) Fuel Sediment Cup Cleaning The sediment cup prevents dirt or water which may be in the fuel tank from entering the carburetor. If the engine has not been run for a long time, the sediment cup should be cleaned. 1) Turn the fuel valve to the OFF position.
  • Page 22: Transporting And Storage

    The gap should be: 0.70-0.80 mm (0.028-0.031 in). 6) Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 7) After the spark plug is seated, tighten with a spark plug wrench to compress the washer. If installing a new spark plug, tighten I/2 turn after the spark plug seats to compress the washer.
  • Page 23 Less than 1 month No preparation required. 1 to 2 months Fill with fresh gasoline and add gasoline conditioner* 2 months to 1 year Fill with fresh gasoline and add gasoline conditioner* Drain the carburetor float bowl. Drain the fuel sediment cup. 1 year or more Fill with fresh gasoline and add gasoline conditioner* Drain the carburetor float bowl.
  • Page 24: Troubleshooting

    Align the notch on the starter pulley with the hole at the top of recoil starter. The disassembled or damaged machine must be transferred to the professional organ for processing. Please make sure that the fuel and lubricant inside the machine have already been drained.
  • Page 25 No electricity at the AC receptacles Is the AC circuit breaker ON Turn the AC circuit breaker ON Check the electrical appliance or Take the generator to an DEFECTS equipment for any defects. authorized generator dealer. Replace the electrical appliance DEFECTS or equipment.
  • Page 26 10. CIRCUIT DIAGRAM...
  • Page 27: Specifications

    11. SPECIFICATIONS Engine type Single cylinder, 4-strokes, Forced air cooling, OHV. Displacement( CC) 389cc Rated speed 3000/min Igniting system Transistor magneto Starting system Recoil Fuel Volume (L) 25 L Continuous operation time (h) Min. Fuel consumption (g/kW.h) 360 g/kW.h Lube. Oil capacity (L) 1.1 L Sound pressure level: L 73.46 dB(A), K = 2.0dB(A)
  • Page 28: Ec Declaration

    FEIDER ZI, 32 RUE ARISTIDE BERGES – 312070 CUGNAUX – FRANCE Declares that the machinery designated below: Gasoline Generator FG4500 Model: Serial number: Complies with the provisions of the Directive “machinery” 2006/42/CE and national laws transposing it: Also complies with the following European directives:...