Site Selection

The Lift is designed for indoor use only. Application in a room with explosion hazard is not permitted. Placing
the lift in a wet place, such as car wash bay, is prohibited. Ensure to check the desired location for possible
obstructions such as a low ceiling, overhead lines, adequate working area, access ways and exits. Make sure
to allow a minimum space of 12 to 14 feet in front and behind the Lift to accommodate all vehicles. Certain
allowances should be made for special vehicle requirements or unusual floor plans.

Surface Condition

Do not use the Lift on any type of asphalt or soft surface. Ensure lift is placed on a dry, oil & grease free, level
concrete surface capable of supporting the weight of the Lift with a vehicle.
expansion seams or cracked, defective concrete. Failure to accomplish the foundation requirement may cause
lift instability, which could result in personal injury.

Operating Condition

Lift is not intended for outdoor use and has an operating ambient temperature range of 41º - 104ºF (5º - 40ºC).
Make sure you have made all necessary measurements to assure that your lift will fit in
your shop / garage and accommodate the car you intend to lift with it. Make sure you
have enough clearance at the top, and enough width to allow walking around. Also, be
aware that the electrical power supply requirements are 115 volt, 1 Phase, 20 amps.

BEFORE USING

Main Lift Components

Fig. 2
7
MSC-6KLP
Sep 2022
Do not use Lift on concrete
power unit