Putting into operation
Check the water inlet sieve for damage.
Do not operate the high-pressure cleaner using the damaged filter.
Be careful when using hot water!
When running your high-pressure cleaner with hot water of 60 °C raised
temperatures occur. Do not touch the metal parts of the high-pressure
cleaner without safety gloves!
22
8.
If using a water inlet filter check it
for cleanliness prior to each startup.
Manually unscrew filter bowl, remove
sieve and thoroughly rinse and clean
with the rest of the parts in clear water.
If the sieve is dirty, water cannot get
through and pressure will not build up.
9.
Connect water hose to water inlet
(minimum requirements; 5 m hose length,
cross-section ¾", 10 bar). The high-pressure
cleaner may be connected to a water
mains (1-10 bar pre-pressure) with either
cold or hot water (up to 60 °C). The
LX-RP-series provides the opportunity
of sucking in water out of a container
(see direct suction).
10. Each time check oil level at the oil
dipstick prior to putting the high
pressure cleaner into operation.
Oil level must be visible in the middle
of the oil sight glass.
Putting into operation
Do not touch the mains plug or any live parts with wet or moist hands.
11. Connect to circuit (see technical data).
The wall socket must be protected on
the mains side by a fuse having a time
lag of at least 20 A (Type C, K).
12. Switch on high-pressure cleaner with
opened safety trigger gun. Bleeding
of the high-pressure cleaner: Pull and
release trigger of safety trigger gun
several times. Start cleaning task.
13. When using the turbokiller lance (option)
make sure that lance points downward
when starting.
14. Adjust operating pressureinfinitely
using the rotary handle. The maximum
pressure is factory-set.
15. The LX-RP-series is equipped with two
holders for the safety trigger gun with
lance.
23