ECA14090
Make sure the rubber damper and rubber
damper holder are flush with the impeller.
Impeller shaft tilt limit
0.15 mm (0.006 in)
1. Straightedge
2. Impeller
EAS26590
INSTALLING THE WATER PUMP
1. Install:
• Water pump assembly "1"
• O-ring "2"
New
Water pump bolt
12 Nm (1.2 m·kg, 8.9 ft·lb)
TIP
• Align the slit "a" on the impeller shaft with the
projection "b" on the oil pump shaft.
• Lubricate the O-ring with a thin coat of lith-
ium-soap-based grease.
2. Fill:
• Cooling system
(with the specified amount of the recom-
mended coolant)
Refer to "CHANGING THE COOLANT"
on page 3-20.
3. Check:
• Cooling system
Leaks → Repair or replace the faulty part.
6-12
WATER PUMP