Figure 4
Manual Reset
Pressure Cut-Off
Power Connection
(See Specification Chart)
1 AMP Control Fuses
(Location of 480V step
down transformer
when required)
Figure 5 - Sensor Installation - Inside Steamroom
NOTE: Location of the sensor is as follows:
a) Single tier seating - 6 feet above floor.
b) Double tier seating - 7 feet above floor.
c) Place sensor on a wall adjacent or opposite of steam head. Do NOT place
sensor above the steam head.
5/8" Hole
No. 8 Plastic
anchors
No. 8 Screws
1" Long
50' sensor cable
Operating Pressure
Control
L1
L2
L3
GND
Control
Heating Elements
Cable to
Steam Generator
1
Temperature
4
Sensor and Housing
(Shipped Assembled)
Heater
Contactor(s)
STEAM 1
Steam Solenoid
Switches
STEAM 2
Box
Control Power
Switch
For Aroma
Pump Only
STEPS TO INSTALL SENSOR:
1) Take new sensor assembly and connect to 50'
sensor cable. Please observe polarity of the 50' cable.
Make sure the male end of the cable is routed toward
the sensor in the steam room.
2) Peel off adhesive backing from sensor.
3) Carefully apply silicone sealant around rear edge.
4) Feed wires back into wall and press sensor firmly to
wall (be careful to align plate holes with anchor holes).
5
5) Install screws, and snap chrome cover back into
place.
6) Temperature sensor assembly must form a 100%
water tight seal to the wall using silicone supplied.
3
Male end
2
11
Control Box Detail View
AROMA 1
AROMA 2
WATER
G
Connect to 120Volt,
N
15AMP Branch Circuit
H
50 Foot Sensor Cable
Aroma Fuse and
Power Light
Aroma Pump
Connection 1
Aroma Pump
Connection 2
12 Volt Control
Transformer
Male end
114416 Rev. D