TROUBlESHOOTING

Problem
Generator will not start
Generator will not start;
Generator starts but runs roughly
Generator will not start electrically
Generator shuts down during operation
Generator cannot supply enough power or
overheating
No AC output
Repeated circuit breaker tripping
for further technical support:
Technical Service
Mon – Fri 8:30 AM – 5:00 PM (PST/PDT)
Toll Free: 1-877-338-0999
tech@championpowerequipment.com
31
Cause
No fuel
Faulty spark plug
Unit loaded during start up
Low oil level
Choke in the wrong position
Spark plug wire loose
Generator battery is dead
Battery switch is in the "OFF" position
Out of fuel
Low oil level
Generator is overloaded
Insufficient ventilation
Cable not properly connected
Connected device is defective
Circuit breaker is open
Faulty brush assembly
Faulty AVR (auto voltage regulator)
Loose wiring
Other
Overload
Faulty cords or device
ENGLISH
Solution
Add fuel
Replace spark plug
Remove load from unit
Fill crankcase to the proper level
Place generator on a flat, level surface
Adjust choke
Attach wire to spark plug
Recharge generator battery
Turn battery switch to "ON" position
Fill the gasoline tank or fill LPG cylinder
Fill crankcase to the proper level. Place
generator on a flat, level surface
Review load and adjust. See "Power
Management"
Check for air restriction. Move to a well
ventilated area
Check all connections
Replace defective device
Reset circuit breaker
Replace brush assembly (Service Center)
Replace AVR (Service Center)
Inspect and tighten wiring connections
Contact the help line
Review load and adjust. See "Power
Management"
Check for damaged, bare or frayed wires.
Replace defective device