6.3 Maintenance work
The following components of the thermal imaging camera in particular can be
replaced by DrägerService:
Rechargeable battery
Window of the IR camera
Softshell cover
6.3.1 Changing the buttons for unlocking and panning
1. Unfasten the retaining ring on the plug-in connector.
2. Remove the buttons and replace with new ones.
3. Secure the buttons with a new retaining ring.
7
Storage
Carry out the following work every 6 months:
Check that the system is functioning correctly:
Switch on the thermal imaging camera and the In-Mask Display and pair
them.
Check that a thermal image is displayed in the In-Mask Display.
Switch the thermal imaging camera and the In-Mask Display off again.
Charge the batteries in the thermal imaging camera and the In-Mask
Display.
Replace the battery when its runtime is no longer sufficient.
Dräger recommends keeping the thermal imaging camera and the In-Mask
Display in their charging cradles so that the rechargeable batteries will be
regularly recharged.
8
Disposal
This product must not be disposed of as household waste. This is indi-
cated by the adjacent symbol.
You can return this product to Dräger free of charge. For information
please contact the national marketing organizations or Dräger.