Enable Event Log Upload To Digi Remote Manager - Digi Connect EZ Mini User Manual

Hide thumbs Also See for Connect EZ Mini:
Table of Contents

Advertisement

Central management
To disable:
(config)> monitoring devicehealth only_send_deltas false
(config)>
When disabled, all metrics are uploaded every Health sample interval.
6. (Optional) Tuning parameters allow to you configure what data are uploaded to the Digi
Remote Manager. By default, all tuning parameters are enabled.
To view a list of all available tuning parameters, use the show command:
(config)> show monitoring devicehealth tuning
all
eth
serial
...
To disable a tuning parameter, set its value to false. For example, to turn off all reporting for
the serial port:
(config)> monitoring devicehealth tuning all serial rx bytes enabled false
(config)> monitoring devicehealth tuning all serial tx bytes enabled false
(config)>
7. Save the configuration and apply the change:
(config)> save
Configuration saved.
>
8. Type exit to exit the Admin CLI.
Depending on your device configuration, you may be presented with an Access selection
menu. Type quit to disconnect from the device.

Enable event log upload to Digi Remote Manager

You can configure your device to upload the event log to Digi Remote Manager, and configure the
interval between event log uploads.
To enable the event log upload, or disable it if it has been disabled, and to change the upload interval:
Digi Connect EZ Mini User Guide
Configure your device for Digi Remote Manager support
rx
bytes
enable true
tx
bytes
enable true
rx
bytes
enable true
tx
bytes
enable true
(config)>