Pre-Operation Check; Break-In; Daily Check - Kubota V2403-CR-TIE4-BG Operator's Manual

Table of Contents

Advertisement

6

PRE-OPERATION CHECK

PRE-OPERATION CHECK

BREAK-IN

During the engine break-in period, observe the following by all means:
1. Change engine oil and oil filter cartridge after the first 50 hours of operation. (See "Changing engine oil" and "Replacing
oil filter cartridge" in "EVERY 400 SERVICE HOURS" (D1803-CR-TIE4, V2403-CR-TIE4) or "EVERY 500 SERVICE
HOURS" and "EVERY 500 SERVICE HOURS OR 1 YEAR" (V2607-CR-TIE4, V3307-CR-TIE4, V3307-TIE4A, V3800-
TIE4) in "REGULAR CHECKS AND MAINTENANCE WORK" section.)
2. When ambient temperature is low, operate the machine after the engine has been completely warmed up.

DAILY CHECK

To prevent trouble from occurring, it is important to know the conditions of the engine well. Check it before starting.
To avoid personal injury or death:
A Be sure to install shields and safeguards attached to the engine when operating.
A Stop the engine at a flat and wide space when checking.
A Keep dust or fuel away from the battery, wiring, muffler and engine to prevent a fire.
Check and clear them before operating every day. Pay attention to the heat of the
exhaust pipes or exhaust gas so that it can-not ignite trash.
1. Parts which had trouble in previous operation
2. By walking around the machine
3. By inserting the key into the starter
switch
4. By starting the engine
Item
(1) Oil or cooling water (coolant) leaks
(2) Engine oil level and contamination
(3) Amount of fuel
(4) Amount of coolant
(5) Dust in air cleaner dust cup
(6) Damaged parts and loosened bolts and nuts
(1) Proper functions of meters and pilot lamps; no stains on
these parts
(1) Color of exhaust fumes
(2) Unusual engine noise
(3) Engine start-up condition
(4) Slow-down and acceleration behavior
Ref. page
-
24
15
17
17 to 19
22
-
-
9
9
8
9

Hide quick links: