Base Connection Line Rs-232 - Pepperl+Fuchs IDM-Z1-264-M-2D-J1-BT-N-N0 Manual

Bluetooth handheld scanner for use in explosion-hazardous areas zone 1/21
Table of Contents

Advertisement

IDM-Z1-264-M-2D-J1-BT-N-N0, IDM-Z1-164-M-1D-J1-BT-P-N0
Commissioning
5.3

Base connection line RS-232

Assignment of pre-installed base connection cable to supply module (RS-232)
Assignment of pre-assembled connec-
tion coupling
Pin
3
2
1
Direct connection of the base station without a plug/coupling to the
supply module with RS-232 interface
The base station can be connected directly to the supply module without using the blue base
connection cable.
The assignment of the serial base station cable CBL-IDM-x61* is outlined in the following table.
Figure 5.15
Assignment of connection cable CBL-IDM-x61* to supply module (RS-232)
Cordset assignment
RJ50 pinout
6
4
7
Note
Information relating to programming from the SICK AG manual (www.SICK.com) is required for
the complete commissioning of the handheld scanner.
24
Core designation
3
2
1
Connection layout
Strand color
White
Brown
Yellow
Supply module terminal compartment
Designation
Number
RxD
X9
GND
X10
PE
X11
GND
X12
+UB
X13
Supply module terminal compartment
Designation
Assignment
TxD
X9
X10
X11
GND
X12
+UB
X13

Advertisement

Table of Contents
loading

This manual is also suitable for:

Idm-z1-164-m-1d-j1-bt-p-n0