System Structure
4.3

System Structure 2

System / Stand-alone setup
Overview of the complete system structure 2: Bluetooth® handheld scanners IDM-Z1-164-
M-1D-J1-BT-P-N0, IDM-Z1-264-M-2D-J1-BT-N-N0, and base station and power module in
explosion-hazardous areas.
Figure 4.2
Description:
The Bluetooth® handheld scanner has been designed with the battery for explosion-hazard-
ous areas. For proper operation in explosion-hazardous areas an IDM-Z1-x64-B-J1-BT-N0
base station, a CBL-IDM-Z1-x61-B-J1* cordset between the base station and the SK-IDM-Z1-
160-BD-1D-J1* supply module, and a connection cable to the power supply are required.
Data can be transferred directly using an HMI system with Bluetooth® interface (e.g., VisuNet
GXP) (option 1) or using the base station, which can be connected to a host PC via the power
supply module and a data line (option 2).
In the case of option 1, the IDM-Z1-x64-B-J1-BT-N0 base station can be used purely as a
charging cradle. A data line to a host PC is not needed in this case.
Figure 4.3
Note
The Supply module is available for RS-232 and USB, make sure to use the compatible RS-232
or USB cables.