Method 3: Suspending groups of columns 2 or 3 panels wide
WARNING!Use minimum two eyebolts and minimum two suspension points per Header when
suspending one independent group 2 or 3 panels wide.
Martin Double and Triple Headers are supplied
in flightcases with Header Connection Brackets
installed (see Figure 7).
If using Martin EC Series Double or Triple
Headers to suspend independent groups of
columns 2 or 3 panels wide from steel cables,
chains or a hoist:
1. Check that the Header Connection Bracket
is firmly fastened to the Headers using the
M12 bolts supplied. Do not use any other
bolts than those supplied by Martin for this
purpose.
2. Attach a steel cable, chain or hoist that is
certified for the weight it will support to each
of the two eyebolts in the tops of Double
Headers or the two outer eyebolts in Triple
Headers, and use these to suspend the
group.
3. Add panels as described in "Suspending
EC Series panels from Headers and other
panels" on page 13.
Method 4: Suspending groups of columns 4 or more panels wide
WARNING! Use minimum one eyebolt and minimum one suspension point per Header if two or more
Double or Triple Headers are fastened together side-by-side in a group four or more panels wide.
If using Martin EC Series Double or
Triple Headers fastened together with
Joining Plates to suspend groups four
or more panels wide from steel cables,
chains or a hoist:
1. See Figure 8. Fasten Double or
Triple Header to each other using
two Joining Plates, one on the top
and one on the front surfaces of the
Headers, securing each plate with
eight of the 8 mm Allen M12 bolts
supplied with each Header (i.e.
sixteen bolts in total). Do not use
any other bolts than the ones
supplied by Martin for this purpose.
2. Attach a steel cable, chain or hoist
that is approved for the weight it will
support to at least one panel
eyebolt per Double or Triple
Header, and use these to suspend
the group of panels.
3. Add panels as described in
"Suspending EC Series panels from
Headers and other panels" on page
13.
12
Figure 7: Header Connection Bracket (Double
Figure 8: Joining Plates for Header Connection Brackets
EC Series user manual
Header illustrated)
8