Reset Button

Reset button and LED — Initiates three levels of reset to the switcher. Use an Extron
H
Tweeker or small screwdriver to press and hold the button while the switcher is running
or while you power up the switcher for different reset levels.
See the ISS 608 and ISS 612 Reset Modes table and
summary of the function of the reset modes and how to perform them.
ATTENTION:
Mode Activation
1
Hold in the recessed rear panel
Reset button while applying
power to the unit.
NOTE:
Do not operate with the default firmware loaded by a mode 1 reset. Use it only to load the most
current firmware to the device.
*4
Hold in the Reset button until
the Reset LED blinks twice
(once at 3 seconds, again at
6 seconds). Then, release and
press the Reset button again
within 1 second*.
*5
Hold in the Reset button until
the Reset LED blinks three
times (once at 3 seconds,
again at 6 seconds, again at
9 seconds). Then, release and
press the Reset button again
within 1 second*.
NOTES:
*For modes 4 and 5, nothing happens if the momentary press does not occur within 1 second.
The factory configured passwords for all accounts on this device have been set to the device serial number.
In the event of a complete system reset, the
User is cleared (see
and the
Review the reset modes carefully. Some reset modes delete all user loaded
content and revert the device to default configuration.
Analysez minutieusement les différents modes de réinitialisation. Certains
modes de réinitialisation suppriment l'intégralité du contenu chargé de
l'utilisateur et remettent l'appareil au mode de configuration par défaut.
ISS 608 and ISS 612 Reset Modes
Result
The ISS reverts to the factory default
firmware for a single power cycle.
Sets the following back to factory
default:
Port mapping
IP address: 192.168.254.254
Subnet mask address:
255.255.255.0
Gateway IP address: 0.0.0.0
Turns DHCP off.
The Reset LED on the rear panel
of the unit flashes four times in
succession.
Performs a complete reset to factory
defaults (except the firmware).
Does everything mode 4 does.
Clears port configurations.
Resets all IP options.
Clears all user settings.
Clears all files from the unit.
The Reset LED on the rear panel
of the unit flashes four times in
succession.
Admin password converts to the default, which is extron ,
Roles and Permissions Panel
ISS 608 and ISS 612 Seamless Switchers • Installation
figure 4
on page 9 for a
Purpose and Notes
Use mode 1 to revert to
the factory default firmware
for a single power cycle if
incompatibility issues arise with
user-loaded firmware. All user
files and settings are maintained.
Mode 4 is used to set
IP address information using
ARP and the MAC address.
Resetting IP Settings
appears on a connected display.
Mode 5 is useful to start over
with default configuration and
uploading, and also to replace
events.
Factory Reset in Progress
displays on a connected display.
Mode 5 is equivalent to
SIS command ZQQQ (see
SIS command
Resets
page 57).
on page 75 to change a password).