7.2 Troubleshooting and Remedial Action

SITUATION
Hoist will not
operate
Hoist will not stop Welded contacts in contactor Replace contactor
Brake slips
Hoist runs but
does not lift
Abnormal sound
on load
chain/chain
sprocket (2 falls)
Electric shock
Oil leak
CAUSE
(1) Broken/disconnected
power or control circuit
wire.
(2) Low supply voltage
(3) Motor hums but does not
rotate
(4) Emergency stop button
release pushed
(5) Faulty contactor
Abrasion of motor brake
(1) Clutch slipping
(1) Chain dry
(2) Worn chain sprocket (2
falls)
(1) Poor earth connection
(2) Accumulated foreign
matter/ moisture on
electrical parts
(1) No oil plug
(2) Loose fitting of oil plug
(3) No plug packing
(4) Worn or deteriorated
oil packing
Locate and repair/reconnect
Check if 10% reduction in voltage, have
main supply checked
Check phases to motor-insulate and repair
Check the cause as necessary
Operate manually if hoist runs then control
circuit/coil is faulty-locate fault and repair.
If hoist does not run then check main
supply. If input supply is correct but there is
a faulty output supply then replace the
contactor
Replace
Contact your authorized Pacific dealer –
this adjustment needs to be carried out on a
test rig
Lubricate
Replace load chain and chain sprocket
(2 falls)
Provide correct earth connection
Remove foreign matter/dry electrical parts
Attach the normal oil plug
Fasten the plug tightly
Attach normal packing
Attach the new packing