Arize Element
L1000 Gen2
®
3.3 Connection Schematic
AC line
Use proper circuit protection level
Driver Input Wire Colors
Black = Line 1
White = Neutral or Line 2
Yellow/Green = Ground
WARNING /
AVERTISSEMENT
Ambient temperature surrounding each
driver must be lower than 113°F (45°C).
/ La température ambiante autour de
chaque module d'alimentation ne doit pas
excéder 113°F (45°C).
4 Connecting Wired Dimming (Optional)
RISK OF ELECTRIC SHOCK
• Turn power off before installation, inspection, cleaning or removal. And
follow appropriate lock out/tag out safety procedure.
• This product must be installed in accordance with the applicable
installation code by a person familiar with the construction and
operation of the product and the hazards involved.
NOTE: Arize L1000 dimming allows user to adjust the light output from 0%/10-100%. When set to 0%, the system will enter standby mode,
consuming 0.5-1.5W and LEDs may remain very faintly lit. If 0 light is preferred, switch off the unit via the mains (AC line).
Remove cap from dimming
1
connector.
N
L3
L2
L1
Driver
REPEAT FOR ENTIRE CIRCUIT BALANCING OUT EACH PHASE
*White = Neutral or Line 2
Optional 3' or 6' inter-connection cable
NOTE: Maximum cumulative length of inter-connection cable is 12 feet.
WARNING / AVERTISSEMENT
RISQUE DE CHOC ELECTRIQUE
• Coupez l'alimentation avant l'inspection, l'installation ou la
• Ce produit doit être installé selon le code d'installation
Plug dimming cable: align
2
keying features and push
connectors together until lock
ring has snapped into place
and a click is heard. To remove
dimming cable, turn locking ring
1/8 of a turn counter-clockwise
and separate connectors.
LED.com
© 2023 Current Lighting Solutions, LLC. All rights reserved. GE and the GE monogram are trademarks of the
General Electric Company and are used under license. Information and specifications subject to change
without notice. All values are design or typical values when measured under laboratory conditions.
3-Phase Y
*
*
*
Driver
Driver
Driver
désinstallation.
pertinent, par une personne qui connaît bien le produit et son
fonctionnement ainsi que les risques inhérents.
Dimming
Switch
+ (0-10V)
- (0-10V)
Connect the appropriate wiring
3
to Dim + (0-10V) and Dim –
(0-10V) from driver. Insulate
the black wire. Follow dimming
switch instructions for rest of
connection.
*The black/white wire is a 12V
auxiliary output that can support
up to 250mA of current.
Installation Guide
3-Phase ∆
Driver Driver
Light module
Dimming
Cable
Black/White (12V)*
Purple
Pink
Page 14 of 15
(Rev 06/20/23)
HORT158 | DOC-2000991