Application; Technical Data - Frank FH 711 DMP Operating Instructions Manual

Table of Contents

Advertisement

Available languages

Available languages

1.

Application

The hot water high-pressure cleaner is used for the cleaning, degreasing, conservation,
deconservation, and desinfection of vehicles, machines, machine parts, equipment, contain-
ers, etc.
2.

Technical data

Machine type
High pressure stage HD
Working pressure
Max. flow rate
Operating temperature
Mitteldruckstufe MD
Working pressure
Max. flow rate
Operating tempera-
ture, max.
Supply voltage
Rated load
Fuel consumption
Heizöl EL, DIN 51603, bei Dauerbetrieb mit max. Betriebstemperatur
Oil tank capacity
Noise emission, sound
level
Dimensions
Length with trolley
Length without trolley
width
Hight
Weight
* measured outside, at a distance of 1 m from the machine surface and 1.6 m above the
ground.
FH 711 DMP
FH 918 DMP
115 bar
180 bar
11,5 l/min
14,5 l/min
90 °C
75 °C
30 bar
30 bar
5,5 l/min
6,5 l/min
140 °C
140 °C
230 V 1 AC /
400 V 1 AC /
60 Hz
60 Hz
2,9 kW
5,3 kW
6,0 kg/h
6,0 kg/h
(7,2 l/h)
(7,2 l/h)
23 Liter
23 Liter
max. 78,5
max. 78,5
dB (A)*
dB (A)*
1245 mm
1245 mm
980 mm
980 mm
590 mm
590 mm
845 mm
845 mm
162 kg
171 kg
FH 1021 DMP
210 bar
17 l/min
70 °C
30 bar
8 l/min
140 °C
400 V 3 AC /
60 Hz
7,3 kW
6,0 kg/h
(7,2l/h)
23 Liter
max. 80
dB (A)*
1245 mm
980 mm
590 mm
845 mm
181 kg
21
FH 1024 DMP FH 1415 DMP
240 bar
150 bar
17 l/min
23 l/min
85 °C
65 °C
30 bar
30 bar
10 l/min
9,5 l/min
140 °C
140 °C
400 V 3 AC /
400 V 3 AC /
60 Hz
60 Hz
7,5 kW
7,5 kW
7,8 kg/h
7,8 kg/h
(9,3 l/h)
(9,3 l/h)
23 Liter
23 Liter
max. 81
max. 79
dB (A)*
dB (A)*
1245 mm
1245 mm
980 mm
980 mm
590 mm
590 mm
845 mm
845 mm
181 kg
181 kg
UK

Advertisement

Chapters

Table of Contents
loading

This manual is also suitable for:

Fh 918 dmpFh 1021 dmpFh 1024 dmpFh 1415 dmp