Parameter Instruction - HIKVISION DS-K3BC411X Series Quick Start Manual

Swing barrier
Table of Contents

Advertisement

(14)
M2 output

3.3 Parameter instruction

Description: the factory has been set up parameters, please do not modify, if you need to
modify the parameters, please proceed under technical guidance.
1. Description
1) The display screen is refers to the main control board of 3 LED display from left to right. Four
buttons: up and down for switch, ENT for sub-menu, ESC for previous menu. Long press "ENT " 3
seconds unlock into the menu.Select advanced parameters, and long press "ENT + Down " 3 seconds
unlock into the menu.
2.Menu setting
Item
1. Parameters
1.1 Counter
1.2 Gate Mode
1.3 PassTimeout
1.4 Memory
1.5 ReadIn Lane
1.6 Open Delay
1.7 CLS. Delay
1.8 Motor1 SPD.
1.9 Motor2 SPD.
Swing Barrier • User Manual
51
GND
Motor
machie
52
+24V
Display pass through count
Set Gate Mode(NO, NC and card, free or reject) of enter and exit
1.NC both Rej
4 NC Card Free 5 .NC Card Rej
7.NC Free Rej
10.NO Both Free 11.NO Both Card
12.NO Card Free 13.NO Free Card
Set maximum waiting time 10-255, unit 0.1s, (default 5seconds)
Set Scan Card With Memory Mode
0 two-way disable(default),1. enter allow,2. exit allow,3. two-way allow
Set Can Scan Card After Entry Lane,Please do not modify
1. disable (default), 2. allow
Set Authorized Open Door Delay 0-255, unit 0.1s, (default 0)
Set Close Door Delay After Passage Finish0-255, unit0.1s, (default 0)
Set master Motor basic speed 1-100
Set vice motor basic speed 1-100
output
for
vice
Explain
2 .NC both free 3.NC both card (default)
6. NC Free card
8.NC Rej Free
9.NC Rej Card
16
Connect to motor of vice
machine

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ds-k3bc411x-lDs-k3bc411x-r

Table of Contents