Answer:Exchange the connect wire of indicator D1 to D2.
Fault 5: Motor idling?
Answer: 1) Check whether the POS Sensor connect wires are loose;2) Turn off the power and use
the millimeter to check whether the connection between the master machine and the vice
machine is continuous.3)Check the vice board 12VGND for voltage output
Fault 6: there is one side of barrier is not closed?
Answer:1)Check whether the POS Sensor connect wires are loose;2)Turn off the power and use
the millimeter to check whether the connection between the master machine and the vice
machine is continuous.3)Check the vice board 12VGND for voltage output
Fault 7: swing the side of the pendulum rod can only open 90 degrees, or open the side of the
pendulum rod hit the box?
Answer:1) check the abnormal barrier and the normal one whether there is any difference
between the fixed angles and whether the pendulum rod is struck or not 2)Check the iron sheet of
core whether is loose, if loose readjust it.
Fault 8: The swing gate move slowly or shake or give big noisy?
Answer:Check core

4.2 Maintenance

Swing /falp barrier gates require regular maintenance by professionals and daily cleaning to
ensure long-term stability and extended equipment life.
1. Maintenance Content:
* Keep the turnstile housing and card reader panels of turnstile gates clean;
* Fasten and lubricate the internal movement structure;
* Check the dust of the driver board and make it cleans.
* Check the connectors and wiring points to ensure the reliability of the connection.
2 Maintenance Methods:
1. Cleaning: Check the housing and card reader panels of the gate, and remove the dust and other
dirt to make them clean;