Debugging Instruction - HIKVISION DS-K3BC411X Series Quick Start Manual

Swing barrier
Table of Contents

Advertisement

2)Access control device connect
Access control device send open signal to control board , gate will open immediately ,The relay
time of access control device must be set to 0-1 seconds.
Main board
Access control device

2.4 Debugging instruction

1)Check wire:Check whether the connection wire of the gate and the power line are properly
connected before power on. If there is any abnormality on the power supply process, check the
connection wires firstly;
2)Function test:After power on the machine will open- close, and open -close, this process is
machine self-check, after the sound from buzzer means finish self-check. Don't stand in the lane in
the process of self-check;
3) The control board will give alarm if stand in the lane without swipe card ;if no response when
infrared sensor be block, please check if the infrared sensors are aligned,Under normal
circumstances, the red led of receive sensor is no bright when no blocked .If the red led of
receive sensor is always bright ,that means the sensors no shoot well ,please adjust to aligned.
4)The relay time of access control device must be set to 0-1 seconds.
5)When the valid card is swiped, the indicator light turn green,If the indicator indicates
incorrect or turn off and alarm immediately when go into first sensor, This means that the signal
connection is opposite, exchange the open signal connect terminal of SW1 Gnd to SW2 Gnd
6)Check and test carefully, running smoothly, no abnormal condition, no impact sound, etc;
Confirm motor is no idle; the indicator light is correct and the infrared pinch function is normal
before putting into use.
Swing Barrier • User Manual
Enter SW Exit SW
SW1 Gnd SW2 Gnd
NC NO COM NC NO COM
12
mark:
SW1---NO
Gnd-----COM
SW2----NO
Gnd-----COM