Technician Level
White

CLEANING PARAMETERS

In this menu the lock time can be set. The lock time defines the period after dispensing the first milk product to the
point where the machine will be locked to force a cleaning. For hygienic matters the machine has to be cleaned at
least once every 24 hours after dispensing a milk product.
Menu
Lock time = 24 h
[ 0 .. < 24 h > .. 24 ]
OUTPUT TEST LEFT / RIGHT
In this menu all the electrical components can be tested for function.
Note: See section VI „Troubleshooting" for further instructions on how to test the following components.
Menu
OUTPUT TEST LEFT / RIGHT
Water Inlet Valve
OUTPUT TEST LEFT / RIGHT
Chamber Release Valve 1
OUTPUT TEST LEFT / RIGHT
Chamber Release Valve 2
OUTPUT TEST LEFT / RIGHT
Brew Valve 1
OUTPUT TEST LEFT / RIGHT
Brew Valve 2
OUTPUT TEST LEFT / RIGHT
Tea Valve
© 2016 by Thermoplan AG, Subject to change
Description
Set the amount of hours that can pass by after the dispense of the first
milk product, until the machine will be locked and a cleaning will be
required.
Description
Press the Enter-key to open the Water Inlet Valve.
The valve is functioning correctly if a „click" noise is heard.
Press the Enter-key to open the Chamber Release Valve 1.
If the brew chamber is closed, a „click" noise is heard.
Press the Enter-key to open the Chamber Release Valve 2.
If the brew chamber is closed, a „click" noise is heard.
Press the Enter-key to open the Brew Valve 1.
If the brew chamber is closed, a „click" noise is heard.
Press the Enter-key to open the Brew Valve 2.
If the brew chamber is closed, a „click" noise is heard.
Press the Enter-key to open the Tea Valve on the boiler.
The valve is functioning correctly if a „click" noise is heard.
REV-6
SECTION III
Service and Technical Manual
3.19