Cleaning; Possible Problems - Thermoplan AGUILA AG220 Service And Technical Manual

Hide thumbs Also See for AGUILA AG220:
Table of Contents

Advertisement

SECTION VI
Service and Technical Manual
Problem
Display message
„Cleaning required in x:xx"
Display message
„Cleaning required!"
Display message
„Cleaning active"
Display message
„Cleaning interrupted!"
Tablets have not
been fully dissolved
6.58
Possible reason
Notice, that the machine will be locked
in x hours / minutes, if its not cleaned.
The machine has to be cleaned at least
24 hours after dispensing the first milk
beverage.
Cleaning was not performed when the
machine asked for it (see „Cleaning
required in x:xx"). The machine is locked
and needs to be cleaned, before any
products can be dispensed.
x Automatic cleaning is running
x Cleaning key was removed during

cleaning

x The milk level tube was not inside the
milk container during cleaning
x Water flow was interrupted
x Power outage during cleaning
x Cleaning tablet valve is defective or
connected wrong
x Filter on cleaning housing is blocked
x Tablets have expired
x Cleaning tablet valve is defective
x Water flow to the cleaning tablet is
interrupted.
x Start the cleaning process before the
timer runs out, to prevent the machi-
ne to get locked.
x Perform cleaning
x Wait until cleaning is completed
x Do not remove the cleaning key while
cleaning is running, restart cleaning
x The milk level tube has to be inside
the milk container during cleaning,
restart cleaning
x Check water cycle, restart cleaning
x Restart cleaning
x Check the cleaning tablet valve in the
service menu „Output Test".
x Clean filter or replace if necessary
x Check the expiry date of the tablets,
do not use expired tablets.
x Check the valve in the service menu
„Output test" and replace if neces-
sary.
x Check water way
REV-5
Black

Possible problems

White
Solution
© 2015 by Thermoplan AG, Subject to change