Most Important Technical Data; Power Supply; Output - Endress+Hauser Ceraphant T PTC31 Operating Instructions Manual

Pressure switch
Hide thumbs Also See for Ceraphant T PTC31:
Table of Contents

Advertisement

Ceraphant T PTC31, PTP31, PTP35
8

Most important technical data

8.1

Power supply

Supply voltage
• DC voltage version
12...30 V DC
Current consumption
• Without load < 60 mA, with reverse polarity protection
Power supply failure
• Behaviour in case of overvoltage
The device works continuously without any damage up to 34 V DC.
If the supply voltage is exceeded, the properties specified are no longer guaranteed.
• Behaviour in case of undervoltage
If the supply voltage drops below the minimum value, the device switches off (status as if not
supplied with power = switch open)
8.2

Output

Switching capacity
• Switch status ON: I
• Switch status OFF: I
• Switching cycles: > 10,000,000
• Voltage drop PNP: ≤ 2 V
• Overload resistance
Automatic load check of switching current; output is switched off in case of overcurrent, the
switching current is tested again every 0.4 s;
max. capacitance load: 14 mF at max. supply voltage (without resistive load)
max. period length: 0.5 s; min. t
Load (analog output)
• Max. (V
supply
Signal on alarm
• Analog output
≤ 3,6 mA / last current value / ≥ 21,0 mA adjustable
(if setting Š 21.0 mA the output is ≥ 21.5 mA)
• Switch outputs
In safe state (switch normally open)
Endress+Hauser
≤ 250 mA
a
≤ 1 mA
a
: 40 ms
on
- 6.5 V) 0.022 A
Most important technical data
29

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ceraphant t ptp31Ceraphant t ptp35