ATTO Technology FastStream SC 5550 Installation And Operation Manual page 74

Table of Contents

Advertisement

SESIdentifyStop
SESIdentifyStop commands the appropriate SES enclosure to
stop identifying the specified element(s). "ALL" stops identifying
all enclosures' drive slots. "RAID" and RAID Group name stops
identifying disks in a RAID Group. "ENC" and enclosure index
stops identifying all slots in the specified enclosure. "DRIVE"
and BlockDevID stops identifying the specified drive. Note that
SESEnclosures must be executed prior to executing
SESIdentify with the parameters ALL or ENC.
SESIdentifyStop [ALL | RAID GrpName <MemberIndex>
| ENC EnclIdx | DRIVE BlockDevID]
SESMute
SESMute causes all known enclosures' audible alarms to be set
to either the "mute" or "remind" state. The default action is
"mute". The enclosure index qualifier is optional. The optional
parameter "REMIND" may be specified to set the "remind"
state, which causes an occasional audible reminder of the
alarm condition (if supported). Note that SESEnclosures must
be executed prior to executing SESMute.
SESMute <EnclIdx> <REMIND>
SESPoll
SESPoll specifies the SES enclosure polling interval, in
seconds. At the specified interval, all known SES enclosures
are polled for their current status. A setting of 0 disables SES
enclosure polling.
set SESPoll [0 | 30 - 3600]
get SESPoll
SESStartingSlot
SESStartingSlot establishes the starting slot/ID number for all
attached SES enclosures.
set SESStartingSlot [0 | 1]
get SESStartingSlot
SESStatus
SESStatus displays the last polled status of the specified
element type in the specified enclosure. SupportLevel indicates
the SES features supported by the specified enclosure:
Fan,Power,Temp,Alarm, DriveLEDs. If no element type is
specified, all status is displayed. Note that SESEnclosures must
be executed prior to executing SESStatus.
SESStatus [EnclIdx | all] <ENC | DRIVE | FAN | POWER
| TEMP | ALARM | SUPPORTLEVEL>
SNTP
SNTP controls whether SNTP time server is enabled.
set SNTP [enabled | disabled]
get SNTP
SNTPServer
SNTPServer sets/displays the main IP address the client uses
to retrieve the SNTP time.
set SNTPServer [xxx.xxx.xxx.xxx]
get SNTPServer
TailEventLog
Displays new events to the terminal. Type quit <ENTER> to Exit
tail mode.
Usage: TailEventLog
Temperature
Temperature returns the current internal operating temperature
in degrees Celsius. The value is read-only.
get Temperature
Time
Time sets/displays the current time in 24 hour format.
set Time [HH:MM:SS]
get Time
TimeZone
Timezone sets/displays the time zone or an offset from GMT.
GMT offset must be in the format +/-HH:MM
set TimeZone [[EST | CST | MST | PST] | [[+|-
][HH]:[MM]]]
get TimeZone
Uptime
Returns the time [days hrs:min:sec] since the last reboot.
Uptime
Username
Username specifies the username used for all sessions: Telnet,
FTP and WebServer. Username is case insensitive, 1 to 32
characters, and cannot contain spaces.
set Username [username]
get Username
VerboseMode
VerboseMode controls the level of detail in CLI 'Help' output and
command response output for the current CLI session.
set VerboseMode [enabled | disabled]
get VerboseMode
VirtualDriveInfo
VirtualDriveInfo displays characteristics and statistics for all the
available virtual drives or any available virtual drive identified by
its virtual drive ID.
VirtualDriveInfo <VirtualDrive ID>
xxiv

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 8550Faststream sc 8250

Table of Contents