ATTO Technology FastStream SC 5550 Installation And Operation Manual page 64

Table of Contents

Advertisement

CAPowerStatus
(CacheAssure Models only)
Returns the current status of the CacheAssure Power Module.
This includes whether or not it is installed and whether or not it
is fully charged.
get CAPowerStatus
ClearEventLog
Clears the contents of the event log.
ClearEventLog
Date
Date sets/displays the current date. The date range is
01/01/2000 to 12/31/2099.
set Date [MM/DD/YYYY]
get Date
DeleteAllMaps
Removes all mapped devices from the map table. Upon the
subsequent POST, if no maps are present the default maps will
be loaded.
DeleteAllMaps
DeleteScheduledTasks
Deletes a scheduled task with the Id returned by
DisplayScheduledTasks.
DeleteScheduledTasks [Id]
DisplayEventLog
DisplayEventLog can be used to enable the "DisplayEventLog"
mode which facilitates scrolling through the event log. The
parameters within the DisplayEventLog are [ + | - | = | q ] The
optional parameter is the number of lines to be displayed as a
single page with no user interaction.
DisplayEventLog <n>
DisplayEventLogFilter
DisplayEventLogFilter is used to filter the display of data for
specified subsystems and levels during "DisplayEventLog"
mode.
Default: all all all
sett DisplayEventLogFilter [subsys | all] [level | all] [all |
none]
get DisplayEventLogFilter [subsys | all] [level | all]
DisplayScheduledTasks
Immediate command that displays all outstanding scheduled
tasks.
DisplayScheduledTasks
DriveAssureReport
Displays drive timeout error statistics for all member drives in
the specified RAID Group.
DriveAssureReport [GroupName]
DriveTest
Immediate command which starts or stops a drive test with the
previously specified configuration and drive list. Drives which
are in-use by the test are not available for RAID configuration or
RAID operations. Only one test can be run at a time.
DriveTest [Begin | Cancel]
DriveTestClearList
Specifies drives to be removed from the drive test list. The 'drive
BlockDevID' parameter will remove the specified drive from the
list. The 'all' parameter automatically removes all drives from the
list.
DriveTestClearList [drive [BlockDevID] | all]
DriveTestConfig
Configures the drive test to perform one of the following
operations: initialize (destructive write-only), mediascan
(destructive for sectors with medium errors), read (non-
destructive read-only), verify (destructive verify), or init-verify
(destructive write-read-verify). The test is not started until the
DriveTest Begin command is given. A new configuration may
not be set while a drive test is being performed.
set DriveTestConfig [init | read | verify | init-verify]
get DriveTestConfig
DriveTestList
Specifies drives to be run in the next drive test. DriveTestConfig
should be setup prior to adding any drives into the test list. This
command can be called with different eligible BlockDev IDs and
each one will be added to the list. Drives which are part of a
RAID Group are only eligible for read drive tests. Additionally,
Hot Spare drives are only eligible for mediascan and read drive
tests. The 'all' parameter automatically chooses eligible drives.
The test is not started until the DriveTest Begin command is
given.
set DriveTestList [drive [BlockDevID] | all]
get DriveTestList
DriveTestStatus
Displays the status of the currently running drive test. This
command does not display performance metrics. If a block
device ID is not running or cannot be found, its state will be 'idle'
and percent complete will be 0.
get DriveTestStatus <drive [BlockDevID]>
DumpConfiguration
Dumps system's configuration.
DumpConfiguration
xiv

Advertisement

Table of Contents
loading

This manual is also suitable for:

Faststream sc 8550Faststream sc 8250

Table of Contents