8.2 Lamp replacement

A
1
H
B
G
C
F
D
E
F85 user's guide – Maintenance
User's Guide – Maintenance
The LAMP indicators on the keypad will turn red when lamp life expires.
Change the lamp when lifetime expires. Always replace lamp with the same type and rating.
USE ORIGINAL LAMPS ONLY.
The lamp includes an electronic lamp timer that is tracking the life time of the lamp.
Always disconnect the power cord and wait until the projector has cooled down (60 min-
utes) before opening the lamp cover. Release the screw (LAMP 1) or (LAMP 2) (see below)
depending on which lamp that needs to be replaced.
Be careful not to touch the protective glass when replacing the lamp,
this may cause the protective glass to overheat and break while in use.
Be extremely careful when removing the lamp module. In the unlikely
event that the bulb ruptures, small glass fragments may be generated.
The lamp module is designed to contain these fragments, but use
caution when removing the lamp module.
A
Remove lamp lid (1 & 2) locking screws.
2
B
Open the lamp lid(s).
C
Unscrew the three locking screws.
D
Pull the lamp out.
Replace with a new lamp in reverse order. When inserting a new lamp,
E
observe the guide pins.
F
Reenter the tree locking screws.
G Close the lamp lid.
H
Turn the locking screw clockwise.
Lamp assembly 1 and 2 are different and have separate article numbers.
Make sure to order the correct one when replacing one of the lamps.
In the unlikely event of a lamp rapture, a limited amount of mercury vapor
may be emitted into the room. To avoid inhailing this mercury vapor
(which is toxic, and can be harmful for lungs and nervous system) the
room should be thoroughly ventilated for a period of at least 30 minutes.
There are no known health hazards from exposure to lamps that are
intact and which are used within an enclosed fixture. No adverse effects
are expected from occational exposure to broken lamps. As a matter of
good practise, avoid prolonged or frequent exposure to lamps unless
there is adequate ventilation. The major hazard from broken lamps is the
possibility of sustaining glass cuts.