Note
If the pressure in the chamber is equal to 0 mbar, the air must be
adjusted with reference to the hatched line on the diagram
(Fig. 16).
 Once the regulation of the head has been concluded, refit
the burner 4)(Fig. 9 to page 15) on the guides 3) at approxi-
mately 100 mm from the pipe coupling 5).
 Insert the electrode cables and then slide the burner as far
as the pipe coupling.
 Replace the screws 2) on the guides 3).
 Fix the burner to the pipe coupling with the screw 1).
On closing the burner on the two guides it is advis-
able to gently pull the high voltage wires outwards
until they are under slight tension.
WARNING
5.11

Fan gate adjustment

The fan gate is set using the indexed selector 1)(Fig. 17), after
having loosened the nut 2).
The first time the burner is fired, this setting should be left as orig-
inally set by the manufacturer: notch 2, see Fig. 17.
6426
Installation
Notches no.
18
GB
D593
Mcal/h
kW
Fig. 16
Fig. 17