4.3

Technical data

Model
Type
Power
(1)
Output
(1)
Fuel
net calorific value
density
viscosity at 20 °C
Operation
Nozzles
Standard applications
Ambient temperature
Combustion air temperature
Electrical supply
Electric motor
Motor capacitor
Ignition transformer
Pump
output (at 12 bar)
pressure range
fuel temperature
Electrical power consumption
Protection level
Noise level
sound pressure
(2)
sound power
Reference conditions: Ambient temperature 20°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Sound pressure measured in manufacturer's combustion laboratory, with burner operating on test boiler and at maximum rated
(2)
output. The sound power is measured with the "Free Field" method, as per EN 15036, and according to an "Accuracy: Category
3" measuring accuracy, as set out in EN ISO 3746.
Technical description of the burner
kW
Mcal/h
kg/h
Kerosene, Gas oil and Blends of gas oil and bio fuel (FAME in accordance
with EN 14214) up to 10%
kWh/kg
Mcal/kg
10.2 (10.200 kcal/kg)
3
kg/dm
6 (1.5 °E - 6 cSt)
2
mm
/s max
Intermittent (min. 1 stop in 24 hours)
Single-stage (all - nothing)
number
°C
°C max
V
Hz
rpm
W
V
A
F/V
V1 - V2
I1 - I2
kg/h
bar
°C max
W max
dB(A)
9
GB
RL 34/1 MZ
975 T
107 - 390
92 - 342
9 - 33.6
GAS OIL
11.86
0.82 - 0.85
2
Boilers: water, steam, diathermic oil
0 - 40
60
230 ~ +/-10%
50/60 - single-phase
2800
300
220 - 240
2.4
12.5/450
230 V - 2 x 12 kV
0.2 A - 30 mA
45
7 - 15
60
600
IP40
68
79
100 - 406
86 - 349
8 - 34
KEROSENE
11.97
10.3 (10.300 kcal/kg)
0.77 - 0.83
6 (1.5 °E - 6 cSt)
32
7 - 15
60
Tab. A
6426

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl 34/1 mz3470511975 t