A Appendix - Accessories (Optional) - Riello 3470510 Installation, Use And Maintenance Instructions

Gas oil/ kerosene burners
Table of Contents

Advertisement

A
Appendix - Accessories (optional)
LONG COMBUSTION HEAD KIT
Burner
RL 34/1 MZ
CLEAN CONTACT KIT
Burner
RL 34/1 MZ
RADIO DISTURBANCE PROTECTION KIT
If the burner is installed in places particularly subject to radio dis-
turbance (emission of signals exceeding 10 V/m) owing to the
presence of an INVERTER, or in applications where the length of
the thermostat connections exceeds 20 metres, a protection kit is
available as an interface between the control box and the burner.
Burner
RL 34/1 MZ
DEGASSING UNIT
It may occur that a certain amount of air is contained in the fuel
sucked up by the pump.
This air may originate from the fuel itself as a consequence of de-
pressurisation or air leaking past imperfect seals.
In double-pipe systems, the air returns to the tank from the return
pipe; in single-pipe systems, the air remains in circulation causing
pressure variations in the pump and burner malfunctions.
For this reason, we advise installing a degassing unit near the
burner in single-pipe installations.
Degassing units are provided in two versions:
Burner
RL 34/1 MZ (without filter)
RL 34/1 MZ (with filter)
Degassing unit characteristics
Burner output
Fuel pressure
Ambient temperature
Fuel temperature
Attachment connectors
(without filter)
Attachment connectors
(with filter)
SPACER KIT
If the burner head penetration into the combustion chamber
needs reducing, varying thickness spacer is available:
Spacer Thickness S
Burner
RL 34/1 MZ
Appendix - Accessories (optional)
Code
3010426
Code
3010419
Code
3010386
Code
20034277
20034281
80 kg/h max
0.7 bar max
40 °C max
40 °C max
FF G 1/4 tank side
FM G 3/8 conic burner side
FF G 3/8 tank side
FM G3/8 conic burner side
Code
(mm)
90
3010095
SOUND PROOFING BOX
If noise emission needs reducing even further, sound-proofing
boxes is available:
Burner
RL 34/1 MZ
CONNECTION FLANGE KIT
A kit is available for use where the burner opening on the boiler
is of excessive diameter
Burner
RL 34/1 MZ
VOLT FREE CONTACT KIT
A volt free contact kit is available for installation onto the burner.
It can be used for a remote interface between burner operationg
signals. Every burner can be equipped with a single kit to remote
the flame presence signal and the burner lockout indication.
Burner
RL 34/1 MZ
PC INTERFACE KIT
To connect the control box to a personal computer for the trans-
mission of operation, fault signals and detailed service informa-
tion, an interface adapter with PC software IS available.
Burner
RL 34/1 MZ
GROUND FAULT INTERRUPTER KIT
A "Ground fault interrupter kit" is available as a safety device for
electrical system fault.
Burner
RL 34/1 MZ
POST-VENTILATION KIT
To have 20 s ventilation after opening of thermostats chain, a
special kit is available.
Burner
RL 34/1 MZ
HOURS COUNTER KIT
To measure the burner working time a hours counter kit is avail-
able.
Burner
RL 34/1 MZ
31
GB
Average
Box type
noise
[dB(A)](*)
C1/3
10
Code
3010138
Code
3010419
Code
3002719
Code
3010448
Code
3010453
Code
3010450
Code
3010403
6426

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rl 34/1 mz3470511975 t

Table of Contents