s
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
SFP Gigabit Transceivers
Order
Mode
t
Code
x
FG51
MM
FG52
SM
FG53
SM
y
FG54
SM
t
Operating temperature range of -40 to 85 °C (-40 to 185 °F), unless specified otherwise.
u
Typical.
v
All optical power numbers are listed as dBm averages.
w
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
x
Operating temperature range of -10 to 85 °C (14 to 185 °F).
y
Operating temperature range of 0 to 70 °C (32 to 185 °F).
GBIC Gigabit Transceivers
Order
Mode
z
Code
FG71
SM
FG72
SM
ad
FG73
SM
z
Operating temperature range of -40 to 85 °C (-40 to 185 °F), unless specified otherwise.
aa
Typical.
ab
All optical power numbers are listed as dBm averages.
ac
Typical distance. The maximum segment length is greatly dependent on factors such as fiber quality, and the number of patches and splices. Consult a Siemens
sales associates when determining maximum segment distances.
ad
Operating temperature range of -25 to 85 °C (-13 to 185 °F).
Section 4.6

Operating Environment

Parameter
Ambient Operating Temperature
Ambient Relative Humidity
Ambient Storage Temperature
Operating Environment
Cable
Connector
Tx λ
Type
Type
(nm)
(µm)
50/125
LC
62.5/125
LC
9/125
1310
LC
9/125
1310
LC
9/125
1550
Cable
Connector
Tx λ
Type
Type
(nm)
(µm)
SC
9/125
1310
SC
9/125
1310
SC
9/125
1550
-40 to 85 °C (-40 to 185 °F)
-40 to 85 °C (-40 to 185 °F)
Tx
Tx
Minimum
Maximum
u
v
(dBm)
(dBm)
850
-9
-2.5
-9.5
-3
-7
-3
0
5
Tx
Tx
Minimum
Maximum
aa
ab
(dBm)
(dBm)
-9.5
-3
-7
-3
0
5
Range
5% to 95%
Technical Specifications
Rx
Rx
Sensitivity
Saturation
v
v
v
(dBm)
(dBm)
-20
0
-19
-3
-23
-3
-23
-3
Rx
Rx
Sensitivity
Saturation
ab
ab
ab
(dBm)
(dBm)
-21
-3
-24
-3
-23
-3
Comments
Ambient Temperature as measured from a 30 cm
radius surrounding the center of the enclosure.
Non-condensing
Chapter 4
Maximum
Power
Distance
Budget
w
(km)
(dB)
0.5
11
0.3
10
9.5
25
16
70
23
Maximum
Power
Distance
Budget
ac
(km)
(dB)
10
11.5
25
17
70
23
31