Technical Specifications

The following sections provide important technical specifications related to the device and available modules:
Section 4.1, "Power Supply Specifications"
Section 4.2, "Failsafe Relay Specifications"
Section 4.3, "Supported Networking Standards"
Section 4.4, "Copper Ethernet Port Specifications"
Section 4.5, "Fiber Optic Ethernet Port Specifications"
Section 4.6, "Operating Environment"
Section 4.7, "Mechanical Specifications"
Section 4.1

Power Supply Specifications

Power Supply Type
24 VDC
48 VDC
d
HI (125/250 VDC)
d
HI (110/230 VAC)
a
(F) denotes fast-acting fuse
b
(T) denotes time-delay fuse.
c
Power consumption varies based on configuration. 10/100Base-TX ports consume roughly 1 W less than fiber optic ports.
d
The HI power supply is the same power supply for both AC and DC.
Section 4.2

Failsafe Relay Specifications

Rated Switching Current
Maximum Switching Capacity
Power Supply Specifications
Input Range
Minimum
10 VDC
36 VDC
88 VDC
85 VAC
Parameter
Max Switching Voltage
Internal Fuse Rating
Maximum
36 VDC
72 VDC
3.15 A(T)
300 VDC
264 VAC
Value (Resistive Load)
2 A @ 240 VAC, 0.15 A @ 125 VDC, 2 A @ 30 VDC
Technical Specifications
Maximum Power
ab
Consumption
6.3 A(F)
2 A(T)
2 A(T)
240 VAC, 125 VDC
150 W, 500 VA