Refilling chemical
disinfectant
Adding and dispensing chemical agents

Chemical disinfectant

Heat-sensitive items, e. g. theatre shoes can be disinfected using a
chemical disinfecting agent.
The disinfecting agent must be suitable for machine use and must be
low-foaming.
Disinfecting parameters are based on claims made by the disinfecting
agent manufacturer. Please observe, in particular, their instructions
on handling, conditions of use and effectiveness.
 Chemo-thermal procedures of this type are not suitable for the
reprocessing of medical devices.
For this application, the cleaning machine must be provided with a
special reprocessing programme and a suitable dispensing module
by the Miele Customer Service Department. The dispensing module
is connected externally.
Place the chemical agent container (green marking) on the open
cabinet door or on a surface which is robust and easy to clean.
Take the lid off the canister and remove the suction lance. Place the
suction lance on the open wash cabinet door.
Replace the empty container with a full one.
Push the suction lance into the opening of the container and secure
the lid. Observe the colour coding.
Feed the suction lance into the container until it reaches the
bottom.
Wipe up any spilled process chemical thoroughly.
Place the container on the floor next to the machine or in an
adjacent cupboard. The container must not be placed on top of or
above the machine. Make sure that the dispensing hose is not
kinked or trapped.
The dispensing system must then be vented (see "Settings /DOS
venting").