Page 1
EziCore BCE Series SKOPE Upright Fridge Hydrocarbon SKOPE IDs: BCE600N:EB60BYN and BCE1200N:EB12BYN...
Page 2
E-mail: skope@skope.com Website: www.skope.com Trademark Infringement The SKOPE trademark on this product is infringed if the owner, for the time being, does any of the following: • Applies the trade mark to the product after its state, condition, get-up or packaging has been altered in any manner •...
1 Specifications Models This service manual is applicable to the EziCore BCE bottom mount fridges listed in the table below. Refer to the relevant product specification sheet (available on the SKOPE website: www.skope.com) for specifications. Table 1: Model specifications Series...
SKOPE EziCore BCE Series 2 Installation Installation Guidelines When installing this cabinet, ensure you consider and meet the installation guidelines below. Ventilation Surface Door Opening Climate Class The installation surface Ensure all ventilation Allow adequate space for The fridge must be installed...
SKOPE EziCore BCE Series Procedure 1: To fit a door handle Before you start Plastic handle 1. Make sure all handle components are ready to assemble. Counterbore hole 2. Ensure you have a screwdriver to fit the Fixing screw mounting hardware.
SKOPE EziCore BCE Series Shelves The wire shelves each sit on shelf clips which slide up and down the shelf support strips inside the cabinet. The shelves may be positioned at different heights to suit various products. The retention clip which sits on the shelf clip doesn’t need to be unlocked to move the shelf clip.
(see below). Setpoint SKOPE does not recommend that the setpoint range be changed unless it is absolutely necessary, and then only by small increments at a time. Procedure 5: To change the temperature setpoint range 1.
SKOPE EziCore BCE Series Messages and The following table explains messages and alarms that the electronic controller displays. Alarms Table 2: Chunchang C212 messages and alarms Display Description The cabinet’s internal temperature. The temperature is what the sensor inside the fridge detects, and not necessarily the product temperature.
Fluorescent or LED tubes cannot be used in place of LED modular lights. IMPORTANT Replace the light with the same SKOPE OEM part. DO NOT use alternative LED strip or tube lights, or fluorescent tubes. Refer to Spare Parts for replacement light specifications: •...
Page 13
SKOPE EziCore BCE Series Procedure 7: To replace an interior light assembly 1. Disconnect the cabinet from the mains power supply (see page 12). Top strip Side strip 2. Gently remove the side and top black Screwdriver plastic strips with a slotted...
Page 14
SKOPE EziCore BCE Series Procedure 8: To replace the LED driver 1. Disconnect the cabinet from the mains power supply (see page 12). 2. Unscrew and remove the kick panel from the front of the cabinet. LED driver Connector cover BCE600N only 3.
Page 15
SKOPE EziCore BCE Series Procedure 9: To replace the sign lighting loom and cabinet lighting loom 1. Disconnect the cabinet from the mains power supply (see page 12). 2. Lift the sign panel so you can unplug the cabinet light...
SKOPE EziCore BCE Series Procedure 9: To replace the sign lighting loom and cabinet lighting loom (continued) 7. Unplug the relevant connectors. • Cabinet lighting loom: unplug the white 4-way connector in the sign panel. • Sign lighting loom: unplug the white 4-way connector, the black 2-way connector, and the switch connectors in the sign panel.
SKOPE EziCore BCE Series Procedure 10: To replace the sign light (continued) 4. Refit the sign’s front panel and reconnect the: • cabinet light connector(s) leading from the hinge. • connector on the top of the cabinet. 5. Reseal the top connector with polyethylene (PE) tape.
SKOPE EziCore BCE Series Procedure 12: To refit the door (continued) 6. Fit the height adjustment block to the bottom screw hole. If necessary, adjust the height of the door (see Procedure 15, “To adjust the door height,” on page 18).
Page 19
SKOPE EziCore BCE Series Procedure 15: To adjust the door height (continued) Bottom hinge 3. Loosen the bottom hinge, and remove the height adjustment block. Height adjustment An outside door block 4. Set the door to the correct height, turn the height adjustment block to the most appropriate angle, refit it, and tighten up the bottom hinge screws.
SKOPE EziCore BCE Series Electronic Controller Controller The electronic controller is located behind the kick panel and sits in a cut-out in the panel. It can be mounted by a snap-fit feature on the controller’s sides. Location Kick panel Controller display Procedure 16: To access the controller 1.
SKOPE EziCore BCE Series Controller To connect the controller, plug the control probe flex and controller power flex into the correct sockets on the controller. To disconnect the controller, simply unplug the control probe flex and Flexes controller power flex.
Ensure you have read and understood this manual before starting any servicing. Important • SKOPE hydrocarbon refrigeration systems must only be serviced by appropriately skilled and qualified refrigeration mechanics. • Servicing a sealed refrigeration system must occur at a hydrocarbon workshop or service area with dedicated hydrocarbon equipment and personal protective equipment (PPE).
The cartridge must only be used on a SKOPE hydrocarbon-compliant cabinet. Refer to the cabinet rating label to determine if the cabinet is suitable for use with a hydrocarbon cartridge.
SKOPE EziCore BCE Series The rating label must state refrigerant as R290. If the label states a different refrigerant, or does not state a refrigerant, it is NOT suitable for a hydrocarbon cartridge. WARNING The hydrocarbon cartridge must only be used on an hydrocarbon-compliant cabinet.
SKOPE EziCore BCE Series It is helpful to have a correctly operating cartridge running beside the cartridge being serviced to compare behaviour. Note: This diagnostic procedure is indicative only. Procedure 18: To determine if there is a sealed system fault Before you start 1.
SKOPE EziCore BCE Series Procedure 19: To remove the refrigeration cartridge (continued) 2. Unscrew and remove the kick panel. 3. Detach the electronic controller assembly from the kick panel. 4. Remove cartridge electrics cover and unplug the mains supply plug and cabinet plugs.
SKOPE EziCore BCE Series Cartridge The cartridge electrics box assembly contains the mains supply socket, EMI filter and panel mount socket connectors for the cartridge and cabinet. Refer to the “Wiring diagram” on Electrics Box page 28 or label on the electrics box cover for the socket connections.
SKOPE EziCore BCE Series Wiring diagram Cartridge Remove the cartridge cover to access parts within the cartridge assembly. Cover Procedure 22: To remove the refrigeration cartridge cover 1. Disconnect the cabinet from the power supply (see page 12). 2. Remove the refrigeration cartridge (see page 25).
Page 29
Refer to the label on the electrics box cover to identify the condenser fan plug and socket in the electrics box. IMPORTANT Replace the motor with the same SKOPE OEM part. DO NOT use alternative parts. It is important that the fan blade and/or fan motor is replaced with the same part to ensure safety, correct alignment and refrigeration performance, and compliance.
(complete with fan motor and fan blade) can be lifted off the evaporator tub once the refrigeration cartridge cover has been removed. IMPORTANT Replace the motor with the same SKOPE OEM part. DO NOT use alternative parts. It is important that the evaporator fan blade and/or fan motor is replaced with the same part to ensure safety, correct alignment and refrigeration performance, and compliance.
Page 31
SKOPE EziCore BCE Series Procedure 26: To access the evaporator fan assembly Before you start If a customer reports a “not cooling” fault, and it has been established that the cabinet is not cooling, follow the “On-site Work Procedure” on page 35.
SKOPE EziCore BCE Series Procedure 28: To replace the evaporator fan motor (continued) Evaporator fan motor’s white 4-way connector 3. Trace the cable back to the connector (near the compressor electrics) and unplug it. 4. Detach the fan motor from the fan mounting bracket by removing the four screws from the mounting bracket.
SKOPE EziCore BCE Series Procedure 29: To replace the control probe (continued) 4. Following the same path as the original probe, fit the new probe with cable ties as necessary. Ensure the probe cable is securely plugged into the rear of the cartridge electrics box, and that it is cable-tied to the evaporator fan shroud bracket, with the probe bent away from the fan bracket at a 45°...
Page 34
SKOPE EziCore BCE Series Procedure 30: To access the compressor electrics (continued) Metal clip 5. Unclip the relay cover from the compressor by releasing the metal clip and screw on the relay cover. Screw 6. Make sure that all terminals in the relay cover are in their correct locations, and not loose or falling off.
SKOPE EziCore BCE Series On-site Work Procedure If a customer reports a “not cooling” fault, and it has been established that the cabinet is not cooling, follow the procedure below when making the service visit. Calibrate the gas Isolate at the Create a 1.5 m...
Page 36
SKOPE EziCore BCE Series On-site work procedure (continued) Return faulty cartridge to service depot: Create a safe work area around faulty Is refrigeration cartridge. Area must be in open well system ventilated space. Ensure no hazards, considered to ignition sources or drains.
SKOPE EziCore BCE Series BCE1200N Table 12: Parts – Cabinet assembly BCE1200N Item Description SKOPE Part No. Front castor – lockable HB0070105065B Rear swivel castor HB0070105066 Kick panel EB12BYN/130A-49 Kick panel stop HB0070203535 Top hinge – left hand HB0070110583 Top hinge – right hand...
SKOPE EziCore BCE Series Glass Door Assembly Table 13: Parts – Glass door assembly Description SKOPE Part No. BCE600N BCE1200N Left hand door assembly HB0070843182 Right hand door assembly HB0070843181 HB0070843183 Door handle HB0070202818 HB0070202818 Door handle cap HB0070202817 HB0070202817...
SKOPE EziCore BCE Series Cartridge Assembly – UBHCNI-0061 Ordering The model and serial number are both printed on the cartridge rating/serial number label attached to the front of the cartridge. Before ordering spare parts, take note of the model and serial numbers.
Page 44
SKOPE EziCore BCE Series Table 15: Parts – Cartridge assembly Item Description SKOPE Part No. EziCore cartridge assembly UBHCNI-0061 Cartridge plastic bottom HB0070206212D Condensate line HB0070702717 Drier bracket HB0070112920 Condensate pipe support HB0070206128 Compressor – Donper L96CU1 HB0074001387A Electrics box assembly (see page 45)
The owner should periodically wipe the inside and outside of the cabinet with a damp cloth, taking care to keep moisture away from electrical parts. Condenser To ensure trouble-free performance, SKOPE strongly recommends the cleaning schedule in Table 17, which will depend on: Coil •...
Page 47
SKOPE EziCore BCE Series Procedure 31: To clean the condenser coil (continued) Condenser coil 3. Check the condition of the condenser coil, and use an appropriate cleaning method: • a nitrogen blow-out. • a PH-neutral chemical clean. 4. Refit the kick panel, and reconnect to the power supply.
Check each parameter individually. Get the latest parameter • Incorrect parameters • Defrost cycle set by registering for and logging into the skope.com incorrect length website, or contacting Customer Service. • Fan not working • Loose plug Check all plugs are connected correctly.
Page 49
Product must not overhang the shelves. Diagnose and repair. If a system fault is found contact • Refrigeration system error (indicated by the electronic controller) SKOPE for information on how to proceed. • Frequent door opening Limit door openings. •...
Need help?
Do you have a question about the EziCore BCE Series and is the answer not in the manual?
Questions and answers