Skope ReFlex Series User Manual

Skope ReFlex Series User Manual

Advertisement

Quick Links

ReFlex Series
User Guide
Thank you for purchasing a SKOPE refrigeration product.

Safety

Always observe safety precautions when using any electrical appliance.
Read these instructions carefully and keep them for future reference.
WARNING
Ensure the appliance is disconnected from the power supply before performing any cleaning or maintenance.
Do not cover the grilles or block the entry or exhaust of airflow by placing objects up against the refrigeration unit.
Should manual defrosting be necessary, turn off the refrigeration system and allow the ice to melt by air circulation. Collect
ice and water during defrost to prevent a slip hazard. Do not use mechanical methods to remove ice, as this may damage
the refrigeration circuit.
Do not use any electrical devices or appliances inside the food storage compartment.
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities,
or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance
by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance.
Do not use this appliance for other than its intended use.
Do not insert fingers/foreign objects into any holes.
Only use this appliance with the voltage specified on the cabinet rating label.
Ensure the appliance has adequate ventilation as this is essential to economical, high performance.
Be careful not to touch moving parts and hot surfaces.
For your own safety and that of others, ensure that all electrical work is done by authorised personnel.
If the power supply flexible cord becomes damaged, it must be replaced by an authorised service agent or similarly qualified
person in order to avoid a hazard.
Ensure all necessary safety precautions are observed during installation or removal of the refrigeration unit.
The appliance is not designed to be stable while in motion. Use extreme caution when moving or transporting it.
Do not store explosive substances such as aerosol cans with a flammable propellant in this appliance.
Do not exceed a maximum load of 20 kg per shelf.
If the cabinet is to be scrapped, ensure the cabinet is unplugged from the power supply and cut off the mains flex close to the
back of the cabinet. Be mindful of the risk of animals or children becoming trapped in the appliance – either remove or secure
doors if necessary.
Refrigerant must be removed by a qualified service person and the cabinet recycled/disposed of in accordance with local
regulations.
This cabinet is designed to operate within a specific climatic class environment.
See the cabinet rating label inside the cabinet for climate class number.
Climate class
Ambient temperature
3
25°C
4
30°C
5
40°C
7 (tropical)
35°C

Door(s)/Drawers

Cabinets may have hinged stainless steel or glass doors, or stainless steel drawers. All cabinets are fitted with key locks, which can
be unlocked with the supplied keys. SKOPE does not recommend opening a door past 90°. The underbench drawers fit GN1/1,
100 mm deep pans as an insert (supplied separately), and the pan top lip maximum height should be no more than 5 mm. The
ChefBase cabinet drawers fit GN2/1, GN1/1 and GN1/6, 100 mm deep pans. (Pans are not supplied with the fridge.)
PRN80190 Rev. 1.94 Aug.2023
The cabinet includes relevant hazard symbols that may be associated with the
cabinet. Refer to the information below for symbol description.
Relative humidity
60%
55%
40%
75%
WARNING
The refrigeration system contains flammable R290 refrigerant.
Do not tamper with it.
The refrigeration system must only be serviced by qualified
personnel.
Page 1 of 4

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ReFlex Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Skope ReFlex Series

  • Page 1 Cabinets may have hinged stainless steel or glass doors, or stainless steel drawers. All cabinets are fitted with key locks, which can be unlocked with the supplied keys. SKOPE does not recommend opening a door past 90°. The underbench drawers fit GN1/1, 100 mm deep pans as an insert (supplied separately), and the pan top lip maximum height should be no more than 5 mm.
  • Page 2 No below clearance required No below clearance required *When installed for continuous duty in a climate class 7 environment (35°C ambient / 75% relative humidity), SKOPE recommends providing 50 mm clearance around the sides and back of the cabinet. Cleaning Before First Use You must thoroughly clean and sanitise the cabinet interior, drawers and food contact surfaces such as the worktop before first use.
  • Page 3 To ensure a safe workplace, carefully examine and make note of how much weight you plan to place on the bench top of the ChefBase fridge. SKOPE recommends no greater than 200 kg for the 2-drawer fridge and no greater than 400 kg for the 4-drawer fridge.
  • Page 4 Take care to keep moisture away from electrical parts. The condenser coil must be kept clean. SKOPE strongly recommends monthly cleaning of the condenser coil and air filter. Do not use hard or sharp tools to clean the coil as these may cause damage.

Table of Contents