Display - MAXA i-290 0106 Installer Manual

Inverter air/water heat pumps with axial fans
Table of Contents

Advertisement

KEY
UP
It allows you to move to a higher menu or to increase the value of a parameter.
DOWN
It allows you to move to a lower menu or to decrease the value of a parameter.
CHRONOTHERMOSTAT
Allows to set the operating bands for thermostation on the room temperature detected by the probe present in the i-CR.
CHANGE SEASON KEY
To change the season press for 3 seconds or switch the heat pump or chiller OFF.
ENTER KEY
It allows you to enter menu or to confirm a parameter.
14.6 DISPLAY
The display is a negative LCD with white backlighting. Below is a list of the main icons with their prevailing meanings.
ICON
DESCRIPTION
Cooling
Heating
Sanitary
Water drop
Manual
Maximum Hz
Chronothermostat
Economy
56
DESCRIPTION
ON Fixed: operation mode Cooling
ON Fixed: operation mode Heating
ON fixed: Sanitary enabled
Flashing: Sanitary in progress
On when the main page displays machine water temperature instead of room temperature.
When the chronothermostat is not active but the "mode" setting is.
ON when maximum Hz function is active.
Visible when the ambient chronothermostat is operative.
Eco mode active (from manual or chrono-programme band).