Remote Control Interface; General Information; Technical Data; I-Cr Installation - MAXA i-290 0106 Installer Manual

Inverter air/water heat pumps with axial fans
Table of Contents

Advertisement

14.

REMOTE CONTROL INTERFACE

14.1 GENERAL INFORMATION
The i-CR is a Modbus remote control with negative LCD and capacitive keys.The device is to be used as a remote machine keyboard with local
temperature detection and replication of on-board control functionality.
The remote control:
• Replicates some functions of the machine control (probe reading, parameter access...).
• Weekly room chronothermostat
• Anti-legionella cycle.
• Alarm history.
In machine panel mode, the menus are those of the machine keyboard. The main page shows the room temperature by default and activates the
operating icons according to the machine functions. In case of an alarm, the alarm code is shown instead of the room temperature.
NOTE:
• It can only be configured with one machine, it is not possible to manage a network of units.
• Arrows can be used to display the current time instead of the room temperature.
14.2 TECHNICAL DATA
Technical data are reported in the tabe below.
Non condensing.
(1)
According to REG UE 811/2013.
(2)
14.3 I-CR INSTALLATION
The control is designed for wall mounting according to DIN 503. Indoor use.
On the back of the control, there are pre-drilled slots to be removed by applying pressure with a screwdriver, so that the holes for fastening can
be drilled.
Before doing so, open the control itself, applying light pressure to the bottom and top of the control, so as to separate the back panel from the
front panel.
Use the back panel and drill the holes in the two slots.
Do not use the panel directly as a template to drill holes in the wall, the electronics could be damaged during this operation.
In detail follow the following steps to open the i-CR:
1) Press the tab down to
54
PARAMETER
Supply voltage
Supply frequency
Power
Insulation class
Degree of protection
Ambient operating temperature
Ambient operating humidity
Ambient storage temperature
Ambient storage humidity
(1)
Overall dimensions
Communication
Air probe
Device class
(2)
Control contribution
(2)
STEP 1
Press
down
release
(1)
STEP 2
2) Tilt the rear
part slightly
3) Separate the 2 parts
i-290
Inverter air/water heat pumps with axial fans
VALUE
12 Vac/dc (± 10%)
50/60 Hz
1,5 VA
II
IP20
-25 °C – 60 °C
0 – 80%
-30 °C – 70 °C
0 – 90%
133 x 80,7 x 24 mm
Serial Modbus RS485 Modbus master
Accuracy of +/- 0,5 °C;
Range 0 °C – 70 °C
4
2%
STEP 3
�l�ngs them on the
long side as indicated