Rayleigh Instruments RI-ENERGYFLOW-3P-MODULAR RI-ENERGYFLOW-HYBRID User Manual page 74

3-phase modular inverters
Table of Contents

Advertisement

Grid Regulation
Safety Regulation
EMC
Grid
Specification
China
Germany
Australia-A
Australia-B
Australia-C
Italy(CEI0-21)
Italy
(CEI0-21 ACEA)
Spain
U.K.
Hungary
Belgium
W-Australia
Greece
France
Bangkok
Thailand
S. Africa
50549
Brazil
0126
Ireland
AS/NZS 4777.2, VDE-AR-N4105, VDE0126-1-1
EN61000-6-1, EN61000-6-2, EN61000-6-
3, EN61000-6-4,EN61000-4-16, EN61000-
4-18, EN61000-4-29
Table 9.1 Grid specification (single-phase)
Output Voltage
Range (Vac)
187-252
184-264
180-265
180-265
180-265
195-264
195-264
196-253
184-264
196-253
184-264
180-260
184-264
184-264
198-242
198-242
180-260
184-264
184-264
184-264
184-264
IEC/EN 62109-1&2, IEC62040-1
Output Frequency
Range (Hz)
49.5-50.2
47.5-51.5
47-52
47-52
45-55
49.8-50.2
49.8-50.2
48-50.5
47-52
49-51
47.5-51.5
45-52
49.5-50.5
47.5-50.4
49-51
47-52
47.0-52
47.5-51.5
59.5-60.5
47.5-51.5
47-52
74
Boot wait
time(S)
30
60
60
60
60
60
60
180
180
300
60
60
180
60
150
60
60
60
60
60
180

Advertisement