Schartec Prime 600 Installation And Operating Instructions Manual page 19

Hide thumbs Also See for Prime 600:
Table of Contents

Advertisement

Increase height
Decrease height
Increase partial opening height
Decrease partial opening height
7. Reversal Height Setting
ATTENTION! The factory setting "0" must not be changed in Europe!
a) Press and hold the SET Button until "1" appears on the display,
then release the button.
b) Press the UP button until "7" shows on the display.
c) Press SET to enter this setting sub-menu. You're now in the reversal
height adjustment mode. A "0" will be shown on the display.
d) Press the UP or DOWN button to increase or decrease the desired
reversal height when closing. The setting can be set between "0"
and "9" on the display. "0" is the factory setting which means the
door will reverse to the completely open position should the door
encounter any object when closing.
 Each number between 1 and 9 means 1/10th to 9/10th's of the
total opening length. E.g. if the display is set to 4, then the
opener will reverse the door only 4/10th's of the total opening
height should the door encounter an obstacle.
e) Press SET to confirm your selection. The display will return to "I I".
8. Partial Opening / Ventilation Setting
a) Press and hold the SET Button until "1" appears on the display, then
release the button.
b) Press the UP button until "8" shows on the display.
c) Press SET to enter this setting sub-menu. You're now in the partial
opening / ventilation setting adjustment mode. A "0" will be shown on
the display.
d) Press the UP or DOWN button to increase or decrease the partial
opening height. The setting can be set between "0" and "9" on the
display. "0" is the factory setting which means the partial opening /
ventilation setting is deactivated.
 Each number between 1 and 9 means 1/10th to 9/10th's of
the total opening height. E.g. if the display is set to 3, then the
opener will open the door 3/10th's of the total opening height.
e) Press SET to confirm your selection. The display will return to "I I".
NOTE: The 2nd button on the remote control is used to control
the partial opening / ventilation function.
50

Advertisement

Table of Contents
loading

This manual is also suitable for:

Prime 1000Prime 1200Prime 600-speedPrime 1000-speed

Table of Contents