3. Travel Speed Setting
CAUTION: Upon changing the travel speed, the opening and closing
positions will need to be relearned. Changing the travel speed will
not take effect until this is done.
a) Press and hold the SET Button until "1" appears on the
display, then release the button.
b) Press the UP button until "3" shows on the display.
c) Press SET to enter this setting sub-menu. You're now in the
speed adjustment mode. The letter "A" and a flashing dot
will be on the display.
d) Press the UP or DOWN buttons to change the speed.
 "A" means 100% full speed (factory setting)
 "8" means 80% of full speed
e) Press SET to confirm your selection. The display will return
to "I I".
ATTENTION: For larger, heavier doors, it is recommended
to reduce the travel speed.
4. Automatic Closing
NOTE: A photocell (safety-light beam) must be connected in
order to use the automatic closing function.
a) Press and hold the SET Button until "1" appears on the
display, then release the button.
b) Press the UP button until "4" shows on the display.
c) Press SET to enter this setting sub-menu. You're now in the
auto-close adjustment mode. A "0" will be shown on the
display.
d) Press the UP or DOWN button to increase or decrease the
desired time . The setting can be set between "0" and "9"
on the display. "0" being auto-close deactivated (and also
the factory setting), "9" being the highest time setting of
135 seconds.
 Each number between 0 and 9 is the number shown
on the display x 15 seconds, and this is the delay of
the auto closing time. E.g. a setting of 5 would be 5 x
15 = 75 second delay before auto-close.
e) Press SET to confirm your selection. The display will return
to "I I".