OPERATOR’S MANUAL SPRAY STAR 1000 Model 1010 Requires 10-160 Boom June, 1999 SMITHCO PRODUCT SUPPORT 1-800-891-9435 Hwy SS and Poplar Avenue, Cameron WI 54822 E-mail: productsupport@smithco.com...
INTRODUCTION Thank you for purchasing a product. Read this manual and all other manuals pertaining to the Spray Star 1000 carefully as they have safety, operat- ing, assembly and maintenance instructions. Failure to do so could result in personal injury or equipment dam- age.
SYMBOLS Read Operator’s Electrical Power No Electrical Manual Power Engine - Stop Engine - Start Engine - Run Temperature Water Engine Oil Light Temperature Gasoline Diesel Glow Plug - On Glow Plug - Off Glow Plug Hour Meter Hour Meter Fuse Hand Throttle Choke - Closed...
Page 5
SYMBOLS Up/Down Arrow Down/Lower Up/Raise Manual No Smoking Moving Parts Operation Step Hot Surface Pinch Point Hydraulic Fluid Lift Arm Tractor Penetration Engage Disengage Ground Speed Fast Slow Forward High Warning Danger Reverse Neutral Caution...
SAFE PRACTICES 1. It is your responsibility to read this manual and all publications associated with this machine. 2. Never allow anyone to operate or service the machine or its optional equipment without proper training and instructions. Never allow minors to operate any equipment. 3.
SAFE SPRAYING PRACTICES Persons engaged in the handling, preparation or application of chemicals must follow accepted practices to insure the safety of themselves and others, 1. WEAR protective clothing including: gloves, hat, respirator, eye protection and skin covering suitable for protection from chemicals being used.
SETUP The Spray Star 1000 arrives from setup and ready for service. Depending on freight conditions the tires, wheels, and steering wheel may have to be installed. The spray system is normally shipped attached to the 1000 Prime Mover. If a spray system is to be fitted to a Prime Mover by a dealer or owner, assemble and attach the components in accordance with the parts drawings in this manual.
SET UP (CONTINUED) 11. Machine should be greased before starting, refer to Spray Star 1000 Parts/Service Manual for location. 12. Attach the Spray Boom and any other Optional Equipment to the Prime Mover, in accordance with instructions in the Spray Star 1000 Parts/Service Manual. The nozzles must be the correct distance above the turf as described in Turf Spraying Guide.
Page 11
CONTROLS & INSTRUMENTS (CONTINUED) I. Spray Boss Control - Engages and disengages speed boss. Forward is engage and all the way back is disengage. When the lever is engaged it sets a stop for the accelerator. The accelerator pedal must be used to maintain this speed.
OPERATION Before operating the Spray Star 1000, become familiar with all controls and functions. Also complete all mainte- nance requirements and read all safety warnings. Knowing the Spray Star 1000 thoroughly, how it operates, and by doing the prescribed maintenance steps, you can expect trouble free operation for years to come. SAFETY Safety needs to always be the concern of an operator of a moving vehicle or any machine with moving parts.
Page 13
OPERATION (CONTINUED) Before using the Spray Star, the operator and spray technician must familiarize themselves with all of the information on chemical spraying contained in the Turf Spray Guide. All testing and calibrating of sprayers is to be done with water, not chemicals. This insures the safety to all involved in performing the calibration operation.
Page 14
OPERATION (CONTINUED) SPRAY TANK AGITATION The gate valve on the suction side of the pump, between the tank and the pump must be open before pump is engaged. Close this valve only when necessary to clean the filter with spray material in the spray tank. Front View Back View A.
Page 15
OPERATION (CONTINUED) If your Spray Star is fitted with a hose reel, there is a third ball valve on the discharge system to supply material to the hose reel. The Quadrajet agitation system operates with four venturi jets in the tank bottom. These jets have replaceable orifice discs which discharge the following amounts of spay material.
Page 16
OPERATION (CONTINUED) One of the most common causes for faulty-pump performance is corrosion inside the pump. Flush the pump and entire system with a solution that will chemically neutralize the liquid pumped. Mix according to manufacturer’s directions. This will dissolve most residue remaining in the pump, leaving the inside of the pump clean for the next use.
This section is intended to offer practical guidelines for the distribution of liquid chemicals over an area of turfgrass such as golf courses, park land, school grounds and lawns. SMITHCO makes no representation as to the suitability of any technique or product for any particular situation. This section is suitable for self-propelled spray vehicles or sprayers mounted onto vehicles.
HOSE & HANDGUN SPRAYING A handgun (hand-nozzle or hand-lance) is used to control and direct the spray pattern to the ground, shrub or tree. They must be constructed of long lasting and noncorrosive materials such as brass, stainless or aluminum. The handgun fits to a hose of any length from the sprayer allowing operator mobility.
NOZZLES (CONTINUED) 3. Disperse the material in a specific pattern that will insure even distribution of chemical across the swath covered by the boom. As shown (to the right) the pattern formed by flat fan (TeeJet) nozzles would show most liquid concentrated at the center, then tapering off where it begins to overlap with the next nozzle-approxi- mately...
CALIBRATION INTRODUCTION Calibrating simply means to adjust a set of variables on the sprayer in order to deliver the desired amount of chemical to a known area of turf. The job of calibrating the sprayer consists of balancing these variables so that your sprayer delivers the desired application rate.
THE NOZZLE CHART METHOD OF CALIBRATION The Nozzle Chart Method is useful when the sprayer nozzles are new or nearly new. It is also the most useful method to employ when the sprayer is equipped with an Electronic Spray Control System. The Electronic Spray Control System does most of the calibration work, it is up to the operator to select the proper combination of nozzle size and ground speed which will deliver the desired application rate.
THE NOZZLE CHART METHOD OF CALIBRATION (CONTINUED) 5. For Sprayer with Electronic Spray Control Systems. On sprayers equipped with Electronic Spray Control Systems such as those manufactured by Raven Ind., Micro-Trak Co. and Dickey-John Co., it is still important to select the right type and size of nozzle for the required operation.
Page 24
THE “128” METHOD OF BOOM SPRAYER CALIBRATION (CONTINUED) The carrying or towing vehicle is to be traveling at the desired speed when it crosses the start line of the measured course. Repeat this procedure and determine the average of the two times. 3.
ABBREVIATIONS AND CONVERSIONS Gallons per minute Centimeters lit/min Liters per minute Decimeters dl/min Deciliter per minute Meter Pounds per square inch Millimeters Kilometers Miles per hour Gallon per acre km/h Kilometers per hour lit/ha Liters per hectare Volume per ACRE ml/ha Milliliter per hectare Volume per Hectare...
EC DECLARATION OF CONFORMITY according to Directive 89/392/EEC SMITHCO INC. (Name of supplier) 34 West Ave. Wayne, PA 19087 USA (Full address of the manufacture - authorized representative established in the Community must also give the business name and address of the manufacture)
Batteries. Wheels and tires. A copy of the warranty for the above items is furnished if necessary with each SMITHCO product. Some states do not allow limitations on how long an implied warranty lasts, or the exclusion or limitations of incidental or consequential damages, so the above limitations or exclusions may not apply to you.
Need help?
Do you have a question about the 1010 and is the answer not in the manual?
Questions and answers