13.5. Network Configuration Object (04h)
13.5.1. Category
Extended
13.5.2. Object Description
This object holds network specific configuration parameters that may be set by the end user. A reset command
(factory default) issued towards this object will result in all instances being set to their default values.
As soon as the used combination of IP address, Subnet mask and Gateway is changed, the module informs the
application by writing the new set to instance #1, attribute #16 in the Ethernet Host Object (F9h).
See also...
•
Communication Settings (page 8)
•
E-mail Client (page 43)
•
Ethernet Host Object (F9h) (page 203)
IMPORTANT
Allowing the following instances to be set by the host application during start-up will inhibit the
possibility to pass conformance tests.
13.5.3. Supported Commands
Object:
Get_Attribute
Reset
Instance:
Get_Attribute
Set_Attribute
Get_Enum_String
13.5.4. Object Attributes (Instance #0)
#
Name
3
Number of instances
4
Highest instance number
(Consult the general Anybus CompactCom 40 Software Design Guide for further information.)
Page 96 of 249
Access
Data Type
Value
Get
UINT16
13
Get
UINT16
21
Network Configuration Object (04h)
Description
Supported number of instances
Highest instance number
SCM-1202-023 Version 2.6