BUILDING INTO FLAMMABLE MATERIAL WITH FIRE WALL
Installation with an insulated, vertical flue pipe
- structure/surround to ceiling
75
(Ceramic stone)
25
(Vermiculite)
Isoleret røgrør
EMNE:
AREAL:
Møbleringsafstand: 800 mm.
Flammable material
Brandbart materiale
Fire wall, e.g. 50 mm Jøtul Firewall, 110 mm brick
Brandmur
or other material with corresponding fireproof and
insulating abilities
F.eks. 50 mm. Jøtul firewall
All distances are in mm
All distances are minimum distances
Drawing
03-03-2017
Date:
number:
14
sr
Constructed/Changed by:
75
25
N/A
04-01-2019
VÆGT:
DATO:
N/A
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
Scan 1003/1004
NAVN:
MATERIALE:
DIMENSION:
C:\Working Folder\Designs\Scan 1003\91003019.idw
STI:
90580001
Tighten the space,
for example with a
glass-gasket
91003016
TG.NR:
KEN
SIGN:
The distance to fire wall (brick) depends on the use of
an insulated flue pipe all the way down to the insert
Konstruktion/omramning mod loft
EMNE:
Cavities are not to
be filled out with
insulation material!
Ceiling
Min. 500 cm
Upper
convection
opening
Min. 350 cm
Lower
convection
opening
Floor
N/A
DATO:
VÆGT:
N/A
AREAL:
Krog Iversen & Co A/S
DK-5492 Vissenbjerg©
2
2
91003019
TG.NR:
KEN
14-01-2019