Ohms
RANGE
400.0Ω
4.000kΩ, 40.00kΩ, 400.0kΩ
4.000MΩ
40.00MΩ
Open Circuit Voltage : 0.4VDC typical
Audible Continuity Tester
Open Circuit Voltage: 0.4VDC typical
Range: 400.0Ω; Accuracy: 1.5% + 6d
Audible threshold: between 10Ω and 120Ω.
Diode Tester
Open Circuit Voltage
< 1.6 VDC
Capacitance
1)
RANGE
500.0nF, 5.000µF, 50.00µF, 500.0µF,
3000µF
1)
Additional 50.00nF range accuracy is not specified
2)
Accuracies with film capacitor or better
3)
Specified with battery voltage above 2.8V (approximately half full battery). Accuracy
decreases gradually to 12% at low battery warning voltage of approximately 2.4V
DCA Current (Clamp-on)
RANGE
400.0A
0A ~ 400.0A
1000A
400A ~ 800A
800A ~ 900A
900A ~ 1000A
1)
Induced error from adjacent current-carrying conductor: < 0.01A/A
2)
Relative Zero
mode is applied to offset the non-zero residual readings, if any
Accuracy
0.8% + 6d
0.6% + 4d
1.0% + 4d
2.0% + 4d
Test Current (Typical)
0.4mA
2) 3)
Accuracy
3.5% + 6d
1) 2)
Accuracy
1.5% + 4d
1.5% + 4d
2.0% + 4d
5.0% + 30d