Gun Flush Box Controller 570262 Operation (continued)
NOTE: The following instructions are not for use with the PrecisionMix II system. See your PrecisionMix II system
manual 308916 for operation instructions.
Single Gun Flush Box
General
1. Complete the operating checklist.
2. If cleaning an electrostatic gun, turn off the electro-
statics (P). See Fig. 20.
Fig. 20
3. Open the Gun Flush Box door. Place the gun (Q) in
the box and close the door. See Figs. 21 and 22.
WARNING
FIRE AND EXPLOSION HAZARD
For Electrostatic Guns: To reduce the
risk of fire, explosion, or electric shock,
always turn off the electrostatics on an
electrostatic gun before placing the gun
in the Gun Flush Box.
Resetting Alarms
To reset an alarm when the alarm light is solid red, turn
the Operator Station switch from MIX to STANDBY.
See Fig. 23. See Troubleshooting, page 22.
Operation
P
Fig. 21
Fig. 22
To reset an alarm when the alarm light is flashing (pot
life alarm), follow the Pot Life Monitor and Alarm
procedure, page 21.
NOTE: The first three PrecisionMix alarms will be reset
by the Gun Flush Box controller to prevent nuisance
alarms during flushing and loading.
Q
684019