Step 1: Lid Switch
Loosen the jam nuts (C) and remove the pneumatic
tubing. Thread the switch (B) up or down until the ball
is even with the Gun Flush Box side plate (D). See
Fig. 7.
B
Switch (B) senses when cover is closed.
Fig. 7
10
684019
Adjustments
C
D
Step 2: Gun Switch
Loosen the jam nut (F). See Fig. 8. Remove both tubes
(G). Thread the switch (E) in or out until the end of the
switch is even with the plastic gun guide and the ball of
the switch extends out about 1/16" (1.6 mm).
F
G
Switch (E) senses when gun is in the box.
Fig. 8
E