Jumper And Switch Settings - Daikin RXL-W Series Service Manual

Inverter pair
Table of Contents

Advertisement

Field Settings for FTX, FVXS Series
4.3

Jumper and Switch Settings

Jumper for FTX18/24, FVXS
Switch for FVXS
on indoor unit
Reference
For the location of the jumper and the switch, refer to the following pages.
FTX18/24: page 25
FVXS: page 27
217
Jumper
on indoor
Function
unit PCB
Fan speed setting when
compressor stops for
JB
thermostat OFF.
(effective only at cooling
operation)
Power failure recovery
function
JC
Switch
Function
PCB
Upward airflow limit
setting
S2W(4)
(SW2-4)
When connected
(factory setting)
Fan speed setting;
Remote controller setting
Auto-restart
OFF
(factory setting)
Exposed or half
embedded installation
Part 7 Trial Operation and Field Settings
SiUS092231E
When cut
The fan stops.
The unit does not
resume operation after
recovering from a power
failure. Timer settings
are cleared.
ON
Set the switch to ON
position when you install
the indoor unit
embedded in the wall to
avoid condensation.