Field Settings
Wireless Remote
1. Slide down the cover and take it off.
Controller
2. Cut the address setting jumper J4.
Caution
Replace the remote controller if you cut a jumper unintentionally.
Jumpers are necessary for electronic circuit. Improper operation may occur if you cut any of them.
4.3

Jumper and Switch Settings

Reference
For the location of the jumper, refer to 18 page.
130
 Be careful not to cut the jumper J8.
Jumper
on indoor
Function
unit PCB
Fan speed setting when
compressor stops for
JB
thermostat OFF.
(effective only at cooling
operation)
Power failure recovery
function
JC
(R25252)
When connected
(factory setting)
The fan stops.
Auto-restart
Part 7 Trial Operation and Field Settings
SiUS041829E
When cut
Fan speed setting;
Remote controller setting
The unit does not
resume operation after
recovering from a power
failure. Timer settings
are cleared.