Daikin RXL-W Series Service Manual page 224

Inverter pair
Table of Contents

Advertisement

Field Settings for FTX, FVXS Series
1
Overview of Settings
Setting items
Brightness
1
Filter cleaning setting
2
Suspend
3
Dry keep
4
Preheating control
5
Room temperature
adjustment (cooling)
6
Room temperature
adjustment (heating)
7
Airflow setting when
8
thermostat off during
cooling operation
Wireless/HA priority
setting during automatic
9
operation
Auto-restart
10
219
Field settings mode
Room temperature adjustment settings may be applied.
When changing the settings, make sure the button was correctly pressed by listening for
the beep sound. (The beep can be heard even if the button is pressed within a setting
which is unavailable. In this case, the setting will be invalid.)
Press the
buttons to change the setting items and the setting values.
Setting items
Setting options
0: OFF
1: Dark
2: Bright
0: Short
1: Long
0: OFF
1: ON
0: OFF
1: ON
0: OFF
1: ON
0: Low 2 (–4°C)
1: Low 1 (–2°C)
2: Standard (0°C)
3: High 1 (+2°C)
4: High 2 (+4°C)
0: Low 2 (–4°C)
1: Low 1 (–2°C)
2: Standard (0°C)
3: High 1 (+2°C)
4: High 2 (+4°C)
0: Keep
1: Soft breeze
0: Wireless
1: HA
0: OFF
1: ON
Setting values
Factory
Setting
Brightness of indoor unit LED lamp
2
Determines the duration/time to display Filter cleaning
N/A
sign.
Activation/Deactivation of Standby electricity saving
(suspend function)
0: Power will still be supplied to the outdoor unit PCB
N/A
after the unit operation stopped.
1: Three minutes after the unit operation stops, the power
supply to the outdoor unit PCB is shut off.
Stops the airflow of indoor unit when the thermostat is
OFF to prevent increase of room humidity.
0: When thermostat is OFF, the fan rotor will still be
0
OPERATING, hence there is airflow.
1: When thermostat is OFF, the fan rotor will be
STOPPED, hence there is no airflow.
Activation/Deactivation of compressor preheating
N/A
0: Deactivation of compressor preheating
1: Activation of compressor preheating
Adjustment of indoor temperature thermistor in cooling
operation
Used for adjustment of room temperature control.
2
Adjustment of indoor temperature thermistor in heating
operation.
Used for adjustment of room temperature control.
2
Airflow setting when indoor unit thermostat is off.
0: Same airflow as "thermostat on"
N/A
1: Lowered to LL tap
Determination of priority control method when HA system
is used.
N/A
0: Wireless remote controller can be used.
1: Temperature setting from wireless remote controller is
disabled.
This setting decides the operation of the unit when the
power supply resumed after a power supply shutdown
(i.e. power failure).
N/A
0: When the power supply resumes, the unit remains in
stopped operation.
1: When the power supply resumes, the unit resumes the
operation before the shutdown of power supply.
Part 7 Trial Operation and Field Settings
SiUS092231E
Confirm/Send
R5000374
Contents

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents