BIGLA30 LOV™ gas fryers manufactured for Non-CE countries use different burners for each type gas. The
burners in fryers built for propane gas have a special gray-colored coating on the burner tiles to enable them to
withstand the higher caloric value of the propane gas. Burners designed for use in propane units may be used in
natural gas applications, but not vice versa.
Natural Gas to Propane (LP) Gas
Full Vat before 10/2010: PN 826-2527
Dual Vat before 10/2010: PN 826-2529
Full Vat after 09/10: PN 826-2965
Dual Vat after 09/10: PN 826-2966
Natural Gas to Propane (LP) Gas
Full Vat before 10/2010: PN 826-2745
Dual Vat before 10/2010: PN 826-2746
Full Vat after 09/10: PN 826-2969
Dual Vat after 09/10: PN 826-2970
Units manufactured for export to CE countries are equipped with "universal" burners that may be used with either
Natural (G20, G25) gas or Butane (G30) and Propane (G31) gasses.
CE Gas Conversion Kits for Units with Gas Valve 810-1715
G20 or G25 (Natural) to G30 or G31 Gas:
before 10/2010 PN 826-2973
after 09/10 PN 826-2975
1. Between G20- and G25-type Natural Gas, adjust the gas pressure at the regulator. (Refer to the CE Standard
Burner Manifold Gas Pressure Chart.) Do not change the orifice.
nd
2. Between a 2
family (G20 or G25) and a 3
a. Change the orifices.
b. Adjust the manifold pressure.
3. Remove the old rating plate and return to Frymaster. Affix the new rating plate included with the conversion
kit in place of the old rating plate stating the gas has been converted.
4. If the destination language changes, replace the rating plate. Call your local service agency or KES for a label
kit. The language of reference will be on the corner of the label.
Non-CE Gas Conversion Kits
Non-CE Gas Conversion Kits for Australia
CE GAS CONVERSION INSTRUCTIONS
rd
family gas (G30 Butane or G31 Propane):
2-8
Propane (LP) Gas to Natural Gas
Full Vat before 10/10: PN 826-2528
Dual Vat before 10/10: PN 826-2530
Full Vat after 09/10: PN 826-2967
Dual Vat after 09/10: PN 826-2968
Propane (LP) Gas to Natural Gas
Full Vat before 10/10: PN 826-2747
Dual Vat before 10/10: PN 826-2748
Full Vat after 09/10: PN 826-2971
Dual Vat after 09/10: PN 826-2972
G30 or G31 to G20 or G25 (Natural) Gas:
before 10/2010 PN 826-2974
after 09/10 PN 826-2976