Inspecting And Handling The Unit; Indoor Unit Installation - Pioneer FB012 Installation Manual

Floor console type ductless split systems
Hide thumbs Also See for FB012:
Table of Contents

Advertisement

4. INSPECTING AND HANDLING THE UNIT

At delivery, the package should be checked and any damage
should be reported immediately to the service agent.
When handling the unit, take into account the following:
Fragile, handle the unit with care.
1
Keep the unit upright in order to avoid compressor
damage.
Choose on before hand the path along which the unit is
2
to be brought in.
Move this unit as originally package as possible.
3
4
When lifting the unit , always use protectors to prevent
belt damage and pay attention to the position of the
unit's centre of gravity.

5. INDOOR UNIT INSTALLATION

5.1 Installation place
The indoor unit should be installed in a location that meets
the following requirements:
There is enough room for installation and maintenance.
(Refer to Fig.5-1 and Fig.5-2)
The outlet and the inlet are not impeded, and the
influence of external air is the least.
The air flow can reach throughout the room.
The connecting pipe and drainpipe could be extracted out
easily.
There is no direct radiation from heaters.
CAUTION
Keep indoor unit, outdoor unit, power supply wiring
and transmission wiring at least 1 meter away from
televisions and radios. This is to prevent image
interference and noise in those electrical appliances.
(Noise
may
be
conditions under which the electric wave is
generated, even if 1 meter is kept.)
≥100mm
installation manual
4
generated
depending
on
≥1000mm
Fig.5-1
700mm
5.2 Install the main body
Fix the hook with tapping screw onto the wall.(Refer to Fig.5-3)
the
Hang the indoor unit on the hook.
(The bottom of body can touch with floor or suspended, but the
body must install vertically.)
195mm
Hook
Hook
Tapping
210mm
Fig.5-2
screw
Washer
<6mm
Fig.5-3
Fig.5-4