Appendix - Recommended Connection Group 2 - Danfoss AK-CC 750A User Manual

Controller for evaporator control
Table of Contents

Advertisement

Appendix - Recommended
connection Group 2
Function
The controller has a setting where you can choose between various
types of installation. If you use these settings, the controller will
suggest a series of connection points for the different functions.
These points are shown below.
Even if your installation is not 100% as described below, you can
still use the function. After use, you need only adjust the divergent
settings.
The given connection points in the controller can be changed if you
wish.
AKV valves
Appl.
No.
Def.
Air
type
of
type
sensor
AKV
Room
1
Air
S3A + S4A S2A
EL
S3A + S4A S2A
Gas
S3A + S4A S2A
2
Air
S3A + S4A S2A
EL
S3A + S4A S2A
Gas
S3A + S4A S2A
3
Air
S3A + S4A S2A
EL
S3A + S4A S2A
Gas
S3A + S4A S2A
4
Air
S3A + S4A S2A
EL
S3A
Gas
S3A
Case
1
Air
S3 +S4
EL
S3 + S4
Gas
S3 + S4
2
Air
S3 + S4
EL
S3 + S4
Gas
S3 + S4
3
Air
S3 + S4
EL
S3 + S4
Gas
S3 + S4
4
Air
S3 + S4
EL
S3 + S4
Gas
S3 + S4
102
Controller - (Module no. 1 point 1-19)
AI1
AI2
AI3
AI4
AI5
AI6
pt1
pt2 pt3
pt4
pt5
pt6
S3A S4A
S3A S4A
S5A
S3A S4A
S5A
S3A S4A
S2B
S3A S4A
S5A
S2B
S5B
S3A S4A
S5A
S2B
S5B
S3A S4A
S2B
S3A S4A
S5A
S2B
S5B
S3A S4A
S5A
S2B
S5B
S3A S4A
S2B
S2C
S2A
S3A S5A
S2B
S5B
S2C
S2A
S3A S5A
S2B
S5B
S2C
S2A
S3A S4A
S2A
S3A S4A
S5A
S2A
S3A S4A
S5A
S2A
S3A S4A
S2B
S3B
S2A
S3A S4A
S5A
S2B
S3B
S2A
S3A S4A
S5A
S2B
S3B
S2A
S3A S4A
S2B
S3B
S4B
S2A
S3A S4A
S5A
S2B
S3B
S2A
S3A S4A
S5A
S2B
S3B
S2A
S3A S4A
S2B
S3B
S2A
S3A S4A
S5A
S2B
S3B
S2A
S3A S4A
S5A
S2B
S3B
RS8HP102 © Danfoss 2018-09
AI7
AI8
AI9
AI10
AI11
pt 7
pt8
pt 9
pt10
pt 11 pt 12
Door
Po
Door
Po
Door
Po
Door
Po
Door
Po
Door
Po
S2C
Door
Po
S2C
S5C
Door
Po
S2C
S5C
Door
Po
S2D
Door
Po
S5C
S2D
S5D
Door
Po
S5C
S2D
S5D
Door
Po
Clean
Blinds
Po
Clean
Blinds
Po
Clean
Blinds
Po
S4B
Clean
Blinds
Po
S4B
S5B
Clean
Blinds
Po
S4B
S5B
Clean
Po
S2C
S3C
S4C
Blinds
Po
S4B
S5B
Clean
Po
S4B
S5B
Clean
Blinds
Po
S4B
Clean
Blinds
Po
S4B
S5B
Clean
Blinds
Po
S4B
S5B
Clean
Blinds
Po
DO1
DO2
DO3
DO4
DO5
pt 13
pt 14
pt 15
pt 16
AKV A
AKV A
Def.
AKV A
Def.
Suction
Drain
AKV A
AKV B
AKV A
AKV B Def. A
Def. B
AKV A
AKV B Def. A
Def. B
Suction Drain
AKV A
AKV B AKV C
AKV A
AKV B AKV C
Def. A
Def. B
AKV A
AKV B AKV C
Def. A
Def. B
AKV A
AKV B AKV C
AKV D
AKV A
AKV B AKV C
AKV D
Def. A
AKV A
AKV B AKV C
AKV D
Def. A
AKV A
Blinds
AKV A
Def.
Blinds
AKV A
Def.
Suction
Drain
Blinds
AKV A
AKV B
Blinds
AKV A
AKV B Def. A
Def. B
Blinds
AKV A
AKV B Def. A
Def. B
Suction Drain
AKV A
AKV B AKV C
Blinds
AKV A
AKV B AKV C
Def. A
Def. B
AKV A
AKV B AKV C
Def. A
Def. B
AKV A
AKV B AKV C
AKV D
Blinds
AKV A
AKV B AKV C
AKV D
Def. A
AKV A
AKV B AKV C
AKV D
Def. A
DO6
pt 17
Rail heat
Rail heat
Rail heat
Rail heat
Rail heat
Rail heat
Def. C
Def. C
Rail heat
Def. B
Def. B
Rail heat
Rail heat
Rail heat
Rail heat
Rail heat
Rail heat
Def. C
Def. C
Rail heat
Def. B
Def. B
AK-CC 750A